G6SK-2F-H DC5 Omron, G6SK-2F-H DC5 Datasheet - Page 3

SMT RELAY

G6SK-2F-H DC5

Manufacturer Part Number
G6SK-2F-H DC5
Description
SMT RELAY
Manufacturer
Omron
Series
G6Sr

Specifications of G6SK-2F-H DC5

Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
2A @ 30VDC
Coil Type
Latching, Dual Coil
Coil Current
28.1mA
Coil Voltage
5VDC
Control On Voltage (max)
3.75 VDC
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Form
2 Form C
Power Consumption
140 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6SK-2F-H-DC5
G6SK2FHDC5
■ Characteristics
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
■ Characteristic Data
Service Life
Contact resistance (See note 1)
Operate (set) time (See note 2)
Release (reset) time (See note 2)
Bounce time
Max. operating frequency
Insulation resistance (See note 3)
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Ambient Humidity
Service life
Weight
1000
500
300
200
100
50
30
20
10
0
2. Values in parentheses are typical values unless otherwise stated.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
4. Data shown are of initial value.
the dielectric strength (except between the set and reset coil).
0.2
Resistive load: 10 mA, 10 VDC
Service life (x10
Ambient temperature: +85˚
0.4
6
operations)
0.6
Conforming to
Telcordia specs.
Conforming to
FCC Part 68
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
0.8
1.0
1000
500
300
200
100
50
30
20
10
0
75 mΩ max.
4 ms max. (mean value approx. 2.5 ms G6S; 2.0 ms G6SU, G6SK)
4 ms max. (mean value approx. 1.5 ms G6S; 2.0 ms G6SU, G6SK)
Approx. 0.5 ms
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute (G6S, G6SU) between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute (G6SK) between coil and contacts
1,500 VAC, 50/60 Hz for 1 minute between contacts of different poles
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
500 VAC, 50/60 Hz for 1 minute between set and reset coils (G6SK)
2,500 V (2 x 10 μS) between coil and contacts for G6S and G6SU
2,500 V (2 x 10 μS) between contacts of different poles
1,500 V (10 x 160 μS) between coil and contacts for G6SK
1,500 V (10 x 160 μS) between contacts of same pole
10 to 55 Hz; 5 mm double amplitude
10 to 55 Hz; 3.3 mm double amplitude
1,000 m/s
750 m/s
-40 to +85°C with no icing; -40 to +70°C with no icing (G6SK, DC24 coil)
5% to 85% RH
100,000,000 operations min. (at 36,000 operations/hour)
100,000 operations min. (2A@30VDC, resistive; 1,200 ops/hr.)
100,000 operations min. (0.5A@125VAC, resistive)
See “Characteristic Data”
Approx. 2g
0.1
Resistive load: 100 mA, 28 VDC
2
Service life (x10
; approx. 75 G
Ambient temperature: +85˚
2
; approx. 100 G
0.2
6
0.3
operations)
0.4
0.5
Low Signal Relay
1000
500
300
200
100
50
30
20
10
0
0.2
Resistive load: 100 mA, 50 VDC
Service life (x10
Ambient temperature: +85˚
0.4
G6S
6
0.6
operations)
0.8
97
1.0

Related parts for G6SK-2F-H DC5