G7J-4A-B-W1-AC100/120 Omron, G7J-4A-B-W1-AC100/120 Datasheet - Page 3

RELAY

G7J-4A-B-W1-AC100/120

Manufacturer Part Number
G7J-4A-B-W1-AC100/120
Description
RELAY
Manufacturer
Omron
Series
G7Lr

Specifications of G7J-4A-B-W1-AC100/120

Relay Type
High Capacity
Coil Voltage Vac Nom
120V
Contact Current Max
25A
Contact Voltage Ac Nom
220V
Contact Voltage Dc Nom
30V
Contact Configuration
4PST-NO
Coil Type
AC
Contact Form
4PST - NO
Coil Voltage
100 VAC / 120 VAC
Contact Rating
25 A at 220 VAC (NO), 8 A at 220 VAC (NC)
Contact Termination
Screw
Mounting Style
Bracket
Power Consumption
1.8 W to 2.6 W
Contact Material
Silver Nickel
Coil Current
21.6 mA
Coil Resistance
5000 Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Engineering Data
Motor Load Performance
Ambient Temperature vs. Must-operate
and Must-release Voltage
Load
Endurance
Maximum Switching Power
G7J 100 to 120 VAC
G7J 24 VDC
DC resistive
load (NO
contact)
DC resistive load
(NC contact)
Number of Relays: 5
Number of Relays: 5
Switching voltage (V)
AC resistive load
(cosφ = 1)
AC inductive load
(cosφ = 0.4)
(NO contact)
Item
Ambient temperature (°C)
Ambient temperature (°C)
AC resistive load
(cosφ = 1)
AC inductive load
(cosφ = 0.4)
(NC contact)
300
3φ, 220 VAC, 2.7 kW (with a inrush current of 78 A and a breaking current of 13 A)
Electrical: 100,000 operations min.
Must-operate voltage
Must-release voltage
Must-operate voltage
Must-release voltage
Endurance
5,000
3,000
1,000
700
500
300
100
70
50
G7J-4A-P, G7J-3A1B-P, G7J-4A-B, G7J-3A1B-B, G7J-4A-T, G7J-3A1B-T
220 VAC (NC contact)
220 VAC (NO contact)
Switching current (A)
Ambient Temperature vs. Coil
Temperature Rise
G7J-4A 100 to 120 VAC
G7J-4A 24 VDC
General Purpose Relay
Number of Relays: 5
Number of Relays: 5
Number of samples: 5
Measurement conditions: Increase and decrease the specified shock
gradually imposed in ±X, ±Y, and ±Z directions three times each with
the Relay energized and not energized to check the shock values
that cause the Relay to malfunction.
Criteria: There must not be any contact separation for 1 ms or greater
with a shock of 100 m/s
a shock of 20 m/s
Button upwards
A1 downwards
Malfunctioning Shock
G7J-2A2B
Unit: m/s
Ambient temperature (°C)
Ambient temperature (°C)
2
2
when the coil is not energized.
2
imposed when the coil is energized or with
Terminals
downwards
Terminals upwards
Not energized
G7J
Energized
Button
downwards
A2
downwards
Shock direction
301

Related parts for G7J-4A-B-W1-AC100/120