G8QW-2C4-05 DC12 Omron, G8QW-2C4-05 DC12 Datasheet - Page 2

no-image

G8QW-2C4-05 DC12

Manufacturer Part Number
G8QW-2C4-05 DC12
Description
Automotive Relay (D7030001-0)
Manufacturer
Omron
Series
G8QWr
Datasheet

Specifications of G8QW-2C4-05 DC12

Relay Type
Automotive
Contact Form
SPDT (1 Form C) Dual
Contact Rating (current)
30A
Switching Voltage
16VDC - Max
Coil Type
Standard
Coil Current
57mA
Coil Voltage
12VDC
Turn On Voltage (max)
6.6 VDC
Turn Off Voltage (min)
0.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C) Dual
Contact Rating @ Voltage
30A @ 12VDC
Control On Voltage (max)
6.6 VDC
Control Off Voltage (min)
0.6 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G8QW-2C4-05DC12
G8QW2C405DC12
Characteristics
Note: External coil suppression will cause a measurable increase in release times and may cause the
Characteristics Reference Data
■ Durability Test Data
2
Max. initial contact voltage drop/resistance
Operate time
Release time
Bounce time
Switching frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Operating ambient temperature range
Humidity
Service life
Mass
G8QN &
G8QW
relay’s characteristic to fall out of the specifications given here.
Relay
Miniature Automotive PCB Relay
Door lock motor
Power window motor (locked)
Power window motor (locked)
Sun roof motor (free)
Horn load
Operate
Release
Mechanical
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
Load type
G8QN/G8QW
250 mV @ 10 A/25 mΩ @ 1 A
10 ms max. (3.5 ms typical) @ 12 VDC
5 ms max. (1.5 ms typical) (see Note)
5 ms max. (0.5 ms typical)
5 ms max. (1.0 ms typical)
18,000 operations per hour
100 MΩ min. at 500 VDC
1.0 mA max leakage at 440 VAC/60 Hz for 1 minute between coil & contacts and
between NO & NC contacts
10-500 Hz, 5 G, 1.5 mm total amplitude
10-500 Hz, 5 G, 1.5 mm total amplitude
100 G half sine 6 ms duration (980 m/s
100 G half sine 6 ms duration (980 m/s
-40°C to 85°C (105°C for high temp type)
35% to 85% RH
1,000,000 operations min.
100,000 operations min. (load dependant)
5.9 g (approx.)
18 - 20 A inrush
34 A
23 A
27 A inrush
3 A steady state
-19 A breaking current
14 A
Current
G8QN
2
2
)
)
11 g (approx.)
200,000
200,000
200,000
100,000
200,000
Cycles tested
G8QW

Related parts for G8QW-2C4-05 DC12