G9EA-1 DC100 Omron, G9EA-1 DC100 Datasheet
G9EA-1 DC100
Specifications of G9EA-1 DC100
G9EA1DC100
Related parts for G9EA-1 DC100
G9EA-1 DC100 Summary of contents
Page 1
... Note: 1. Relays come with two M5 screws for the main terminals (contacts). 2. Relays with coil terminals and screw terminals come with two M3.5 screws. Terminals Contact form Contact terminals Screw terminals SPST-NO DC Power Relays (60-A, 100-A Models) Rated coil voltage Model 12 VDC G9EA-1-B 24 VDC G9EA-1 48 VDC G9EA-1-B-CA 60 VDC 100 VDC G9EA-1-CA G9EA-1 1 ...
Page 2
... Approx age Approx. 5.2 W Approx. 5.4 W G9EA-1(-B)- 400 VDC 100 A 400 G9EA-1(-B)-CA 10 mΩ max. (0.3 mΩ typical) 0.1 V max. (for a carry current of 100 A) 400 VDC 1,000 ops. min. 120 VDC 2,500 ops. min. — 150 A (10 min) — 100 A at 120 VDC (150 times min.) — ...
Page 3
... Engineering Data ■ G9EA-1(-B) Switching/Current Conduction Models Maximum Switching Capacity 1,000 500 300 G9EA-1 DC resistive load 100 100 300 500 1,000 Switching voltage (V) Carry Current vs Energizing Time 100,000 10,000 1,000 100 100 300 500 1,000 Carry current (A) ■ G9EA-1(-B)-CA High-current Conduction Models ...
Page 4
... All G9EA-1 Models Must-operate Voltage and Must-release Voltage Distributions 30 Sample: G9EA-1 Must-operate voltage Number: 35 Must-release voltage 100 Percentage of rated voltage (%) Vibration Resistance 10.0 Sample: G9EA-1 Number: 5 8.0 6.0 4.0 2.0 Must-release voltage 0.0 Must-operate voltage − 2.0 − 4.0 − 6.0 − ...
Page 5
... Terminal Arrangement/ Internal Connections (TOP VIEW) 1 (+) (− Note: Be sure to connect terminals with the correct polarity. Coils do not have polarity. Mounting Hole Dimensions (TOP VIEW) Two 6.5-dia. holes 67.2 60.7 61± (Terminal height) 0.1 10.5 24± 0.1 G9EA-1 0.1 5 ...
Page 6
... DC Power Relays (60-A, 100-A Models 13 Dimensions of cutouts for wiring Two, M5 61± 88 0.1 24± 0 G9EA-1 Note: Be sure to remove the cutouts for wiring that are located in the wiring 36 outlet direction before installing the Terminal Cover. Dimension Tolerance (mm) (mm) ±0 lower ±0 ± higher Dimension Tolerance ...
Page 7
... M5 screws: 1.57 to 2.35 N·m • M4 screws: 0.98 to 1.37 N·m • M3.5 screws: 0.75 to 1.18 N·m 2. The G9EA and G9EC Relays’ contacts have polarity. Be sure to perform connections with the correct polarity. If the contacts are connected with the reverse polarity, the switching characteristics specified in this document cannot be assured ...
Page 8
... MEMO 8 DC Power Relays (60-A, 100-A Models) G9EA-1 ...
Page 9
... Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. DC Power Relays (60-A, 100-A Models) G9EA-1 9 ...
Page 10
... European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information. OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Specifications subject to change without notice G9EA-1 Printed in USA ...