M7E-12DKN2 Omron, M7E-12DKN2 Datasheet - Page 7

no-image

M7E-12DKN2

Manufacturer Part Number
M7E-12DKN2
Description
Thumbwheel Switch
Manufacturer
Omron
Series
M7Er
Datasheet

Specifications of M7E-12DKN2

Number Of Digits/alpha
1
Size / Dimension
*
Digit/alpha Size
4.75" (120mm)
Display Type
7-Segment
Common Pin
*
Color
Red
Voltage - Forward (vf) Typ
*
Current - Test
*
Millicandela Rating
*
Wavelength - Peak
*
Power Dissipation (max)
*
Emitting Color
Green/Orange/Red
Number Of Digits
1
Package Type
Module
Operating Supply Voltage (typ)
3.3/5V
Operating Supply Voltage (max)
5.5V
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
16
Opto Display Type
Module
Pattern Type
Segmented
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Package / Case
-
Lead Free Status / Rohs Status
Compliant
Other names
M7E12DKN2
■ Serial Transmission Control Examples
1. 1234 is displayed.
Note: The transmission data is hexadecimal.
2. −123 is displayed.
3. 12.34 is displayed.
4. 9.876 is displayed.
■ A Variety of Control Operations with Short-circuit Sockets
By removing the rear cover of the Display Unit and setting the XJ8A-0211 Short-circuit Socket, the following control operations are possible.
1. DP (J5)
2. RBI (J9)
3. R (J8)
Transmission data
1234
Transmission data
A123
Transmission data
DCDD
Transmission data
1234
Transmission data
CDDD
Transmission data
9876
Note: 1. All the terminals are short-circuited before shipping. Short-circuit or open the terminals according
TER (J11)
G (J10)
2. Single-color (red or green) models do not incorporate the R (J8) and G (J10) terminals.
3. These terminals must be open when controlling the DP (J5), R (J8), and G (J10) terminals
4. All the terminals J5 to J11 are connected to GND.
5. The 80-mm Model uses DIP switches. ON: Short-circuited OFF: Open
to the application.
externally by inputting signals from the CN1. (The short-circuit socket will take precedence.)
(SEL1 and SEL2 are switches to adjust brightness.)
Decimal Control
• Short-circuit the DP (J5) terminals with a short-circuit socket so that the decimal point will be
• The short-circuit socket is short circuited at the factory (i.e., normally lit). Open the short-circuit
Zero Suppression Control
• When the zero suppression function is not used, the RBI (J9) terminals must be open. The TER
• When zero suppression is not used, the RBI (J9) terminals of the M7E Digital Display Unit for
Example of Zero Suppression Setting for Four Digits on the M7E (120/
200-mm Model)
Note: To use zero suppression, CN2 and CN3 must be connected with an M7E-
Example of Zero Suppression Setting for Four Digits on the M7E (80-
mm Model)
Display Color Control (Three-color Model Only)
• Short-circuit the R (J8) terminals with a short-circuit socket so that the display will be lit in red.
• Short-circuit the G (J10) terminals with a short-circuit socket so that the display will be lit in
• Short-circuit the R (J8) as well as G (J10) terminals with two short-circuit sockets so that the
Note: When the R (J8) as well as G (J10) terminals are open, the display will be OFF if the CN1
→ Display
→ Display
→ Display
→ Display
→ Display
→ Display
always lit.
socket if external control or lighting are not required
(J11) terminals can be either short-circuited or open.
the leftmost digit must be short-circuited, those of all the other M7E Digital Display Units must be
open, the TER (J11) terminals of the M7E Digital Display Unit for the rightmost digit must be
open, and those of all the other M7E Digital Display Units must be short-circuited.
green.
display will be lit in orange.
RBI (J9)
TER (J11)
WH@11A Harness Connector.
Input Connector has not been connected yet.
RBI
TER
9.
1
1
1
Leftmost digit
1.
2.
2.
2
1
8
Short-circuited
Short-circuited
M7E
3
2
2
3
3
7
ON
ON
4
3
3 (The decimal point
4 (Numeral data is
4 (The decimal point
6 (Numeral data is
Short-circuited
is controlled first.)
transmitted next.)
is controlled first.)
transmitted next.)
Open
M7E
M7E-WH@11A
OFF
ON
Short-circuited
M7E
Open
OFF
ON
Rightmost digit
Open
Open
5. 4.2-1 is displayed.
6. The displayed decimal point will be OFF.
7. Changing the numeral and decimal point simultaneously.
8. Turn OFF the display by sending data F.
Note: DP and BI control using serial transmission is not displayed in
OFF
OFF
Transmission data
42A1
Transmission data
DDDD
Transmission data
C311
Transmission data
DDDD
Transmission data
32F1
M7E
(It is, however, impossible to change the numeral and decimal
point on the same digit simultaneously.)
hexadecimal.
→ Display
→ Display
→ Display
→ Display
→ Display
• Pins 1 to 4 are all factory-set
• Pins 5 and 6 are factory-set
DIP Switch
to OFF.
for brightness adjustment. Do
not change the setting of
these pins; the brightness will
change.
ON
4.
1 2 3 4 5 6
4
4
4
3
80-mm Model
2
2
3
3
2
1
1
1 (Numeral setting
1
1
4 (The decimal
1
is possible.)
point is OFF.)
(Display turns OFF
with F transmission.)
Short-circuit
socket
SW1
M7E
7