MKS2XTI-11 AC24 Omron, MKS2XTI-11 AC24 Datasheet

no-image

MKS2XTI-11 AC24

Manufacturer Part Number
MKS2XTI-11 AC24
Description
MKS DC Square Base
Manufacturer
Omron
Datasheet

Specifications of MKS2XTI-11 AC24

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
MK-S-series Relays with DC-
switching Models That Can Switch
220 VDC, 10 A (Resistive Load).
Ordering Information
General-purpose Relays
Models for DC Loads
Models for AC Loads
Accessory (Order Separately)
Connecting Socket
• Switch a DC load of 220 VDC, 10 A (resistive load).
• Lineup includes models with SPST-NO and SPST-NO/
• Using a SPST-NO/SPST-NC contact form enables
• Models are also available with a built-in test button.
• Models for AC Loads can switch 250 VAC, 15 A (resistive
• RoHS compliant.
Type
Standard Models
Models with Built-in
Operation Indicators
Models with Test Button
Models with Test Button and
Built-in Operation Indicators
Type
Standard Models
Models with Built-in
Operation Indicators
Models with Test Button
Models with Test Button and
Built-in Operation Indicators
Back-connecting Socket PCB Terminals
Power Relays
MK-S(X)
SPST-NC contact forms.
detecting contact welding. (When the NO contacts
become welded, the NC contacts will maintain a minimum
distance of 0.5 mm.)
load).
New Product
Contact form
Contact form
Classifications
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
Rated coil voltage (V)
Rated coil voltage (V)
SPST-NO
SPST-NO
P7M-06P
Model
MKS1T-10
MKS1TN-10
MKS1TI-10
MKS1TIN-10
MKS1XT-10
MKS1XTN-10
MKS1XTI-10
MKS1XTIN-10
Model
Model
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
AC: 24, 100, 110, 120, 200, 220, 230, 240
DC: 12, 24, 48, 110, 220
Rated coil voltage (V)
Rated coil voltage (V)
SPST-NO/SPST-NC
SPST-NO/SPST-NC
MKS2XT-11
MKS2XTN-11
MKS2XTI-11
MKS2XTIN-11
MKS2T-11
MKS2TN-11
MKS2TI-11
MKS2TIN-11
Model
Model
1

Related parts for MKS2XTI-11 AC24

MKS2XTI-11 AC24 Summary of contents

Page 1

... DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 MKS1TI-10 DC: 12, 24, 48, 110, 220 AC: 24, 100, 110, 120, 200, 220, 230, 240 MKS1TIN-10 DC: 12, 24, 48, 110, 220 Model P7M-06P SPST-NO/SPST-NC Model MKS2XT-11 MKS2XTN-11 MKS2XTI-11 MKS2XTIN-11 SPST-NO/SPST-NC Model MKS2T-11 MKS2TN-11 MKS2TI-11 MKS2TIN-11 1 ...

Page 2

MK-S(X) Specifications Ratings Operating Coil Item Rated current (mA) Rated voltage ( 110 96.3 100 26.6 23.1 110 24.2 21.0 120 22.2 19.3 AC 200 13.3 11.6 220 12.1 10.5 230 11.5 10.0 240 11.0 ...

Page 3

Contact Ratings for Models for DC Loads Contact form Model Load Resistive load Item NO Contact configuration NC Contact material 220 VDC Rated load NC NO Rated carry current NC NO Max. switching voltage NC NO Max. ...

Page 4

MK-S(X) Characteristics Contact resistance *1 Operate time *2 Release time *2 Mechanical Max. operating frequency Rated load Insulation resistance *3 Between coil and contacts Dielectric Between contacts of different polarity 2,500 VAC 50/60 Hz for 1 min between strength Between ...

Page 5

... Ambient Temperature vs. Must Operate Voltage and Must Release Voltage MKS2XT-11 AC Specification (60 Hz) 100 Must operate Number of Relays: 5 voltage Must release voltage − Ambient temperature (°C) MKS2XT-11, MKS2XTN-11 MKS2XTI-11, MKS2XTIN-11 100 DC resistive load DC resistive load L resistive load 1 L resistive load NC NC 0.3 ...

Page 6

MK-S(X) Test Button The circuit can be checked using either of two modes. Test Button DC specification: Blue AC specification: Red Test Button Applications Example: Checking operation of Relays and sequence circuits. 6 Mode 1 Normal (momentary) Press the button ...

Page 7

... The contact terminals on Models for DC Loads have polarity. Wire properly using the correct polarity. 34.5 max. 34.5 max. 0.8 44 max. 7.3 3.5 34.5 max. 34.5 max. 0.8 44 max. 7.3 MKS2XT-11 MKS2XTI-11 AC specification (+) 6 (+) 8 8 (+) MKS2T-11 MKS2TI-11 AC specification MK-S(X) (Unit: mm) 0.5 29.7 MKS2XTN-11 MKS2XTIN-11 DC specification AC specification (+) 4 6 (+) 8 (+) 8 (+) (+) B (−) MKS2TN-11 MKS2TIN-11 DC specification AC specification (+) B (− ...

Page 8

MK-S(X) Connecting Socket Back-connecting Socket P7M-06P 43 max. 8 Terminal Arrangement/Internal Connections Dimensions (Bottom View) 39 max max. A 21.9 4.35 22.1 7.7 0.9 8.3 5.5 PCB Mounting Holes (Bottom View 0 5.5 8.3 ...

Page 9

... Back-connecting Socket PCB terminals PYC-A2 One Set (Two Clips) 5 max. 42.8 4.5 4.5 1.2 Note: The minimum order for the PFC-A2 is ten clips. Socket Mounting Height MKS1XT-10 MKS2XT-11 MKS1XTI-10 MKS2XTI-11 MKS1XTIN-10 MKS2XTIN-11 MKS1T-10 MKS2T-11 MKS1TI-10 MKS2TI-11 MKS1TIN-10 MKS2TIN-11 P7M-06P PYC- MK-S(X) MK-S(X) 9 ...

Page 10

MK-S(X) Safety Precautions Precautions for Correct Use Installation • Models for DC Loads (i.e., models with “X” in the model number) have permanent magnets built into the insulating block, so magnetic interference will occur and contact switching capacity will be ...

Page 11

... OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE ...

Page 12

... Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Authorized Distributor: © OMRON Corporation 2008 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan Cat. No. J175-E1-01 ...

Page 13

... Cat. No. J175-E1-01 OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Rights Reserved. 2008. 11 ...

Related keywords