PYF08A Omron, PYF08A Datasheet - Page 3

no-image

PYF08A

Manufacturer Part Number
PYF08A
Description
NEW P/N PYF08A-E
Manufacturer
Omron
Series
PYFr
Datasheets

Specifications of PYF08A

Accessory Type
Socket, Front Mounting
Associated Relay Series
MY
Number Of Poles
2
Termination Style
Screw
Mounting Style
DIN Rail
Width
22 mm
Socket Mounting
DIN Rail
Current Rating
7A
Socket Terminals
Screw
Voltage Rating
250VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PYF08A
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
PYF08A-E
Manufacturer:
OMRON
Quantity:
2 000
Part Number:
PYF08A-E
Manufacturer:
OMRON欧姆龙进口
Quantity:
20 000
Company:
Part Number:
PYF08A-E
Quantity:
1 655
Part Number:
PYF08A-K3FM
Manufacturer:
NEC
Quantity:
21
Part Number:
PYF08A-N
Manufacturer:
OMRON
Quantity:
100
■ Characteristics
Note: 1. Add ±10 mS to the above value for the 0.5-S range model.
Accuracy of operating time
Setting error (see note 1)
Reset time
Reset voltage
Influence of voltage (see note 1)
Influence of temperature (see note 1) ±2% FS max.
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Impulse withstand voltage
Noise immunity
Static immunity
Enclosure rating
Weight
EMC
Approved standards
2. Terminal screw sections are excluded.
±1% FS max. (0.5 s range: ±1%±10 ms max.)
±10%±50 ms FS max.
Min. power-opening time: 0.1 s max. (including halfway reset)
10% max. of rated supply voltage
±2% FS max.
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying
metal parts) (see note 2)
2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output) (see note 2)
2,000 VAC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model) (see note 2)
1,500 VAC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz, 0.75-mm single amplitude
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude
Destruction: 1,000 m/s
Malfunction: 100 m/s
Operating:
Storage:
Operating:
Mechanical:10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
Between power terminals:
3 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1 kV for 12 VDC, 24 VDC, 48 VDC
Between exposed non-current-carrying metal parts:
4.5 kV for 100 to 120 VAC, 200 to 230 VAC, 100 to 110 VDC, 125 VDC
1.5 kV for 12 VDC, 24 VDC, 48 VDC
±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Destruction: 8 kV
Malfunction: 4 kV
IP40
Approx. 50 g
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity Burst:
Immunity Surge:
UL508, CSA C22.2 No. 14, Lloyds
Conforms to EN61812-1 and IEC60664-1. (2.5 kV/2 for H3Y-2/-2-0, 2.5 kV/1 for H3Y-4/-4-0)
Output category according to EN60947-5-1.
H3Y-2: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h)
H3Y-4: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h)
35% to 85%
–10°C to 50°C (with no icing)
–25°C to 65°C (with no icing)
2
(approx. 10G)
2
(approx. 100G)
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
EN61000-4-2: 8 kV air discharge (level 3)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
EN61000-4-4: 2 kV power-line (level 3)
EN61000-4-5: 2 kV line to ground (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
H3Y
3