R99-01 FOR G6DS Omron, R99-01 FOR G6DS Datasheet - Page 2

no-image

R99-01 FOR G6DS

Manufacturer Part Number
R99-01 FOR G6DS
Description
Tool For P6DS Socket
Manufacturer
Omron
Datasheet

Specifications of R99-01 FOR G6DS

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
■ Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Contact Ratings
Note: P level: λ
■ Characteristics
Note: 1. The data shown above are initial values.
132
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value) (See note.)
Contact resistance (See note 1.)
Operate time
Release time
Insulation resistance (See note 2.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
2. “Max. voltage” refers to voltage that can be applied to the relay coil momentarily. Do not apply "Max. voltage" continuously.
2. The contact resistance is derived using voltage drop method with 1 A applied at 5 VDC.
3. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
PCB Relay
60
= 0.1 × 10
Item
Item
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
−6
operation
G6DS
5 VDC
36 mA
139 Ω
70% max. of rated voltage
5% min. of rated voltage
160% of rated voltage (at 23°C)
Approx. 180 mW
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min. (at 500 VDC)
3,000 VAC, 50/60 Hz for 1 min. between coil and contacts
750 VAC, 50/60 Hz for 1 min. between contacts of same polarity
6,000 V (1.2 × 50 μs) between coil and contacts
10 to 55 to 10 Hz, 1.5-mm double amplitude
10 to 55 to 10 Hz, 1.5-mm double amplitude
1,000 m/s
150 m/s
20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. for standard type; 80,000 operations min. for high sensitivity type (1,800
operations/hr @ 23°C)
Operating: −40°C to 85°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 2.3 g
5 A at 250 VAC, 5 A at 30 VDC
5 A
250 VAC, 30 VDC
5 A
1,250 VA, 150 W
5 mA at 24 VDC
2
(standard type); 130 m/s
2
12 VDC
15 mA
800 Ω
Resistive load (cos φ=1)
Standard
24 VDC
7.5 mA
3,200 Ω
2
(high-sensitivity type)
5 VDC
24 mA
208 Ω
Approx. 120 mW
2 A at 250 VAC, 2 A at 30 VDC
Inductive load (cos φ=0.4, L/R=7 ms)
High-sensitivity
12 VDC
10 mA
1,200 Ω
24 VDC
5 mA
4,800 Ω

Related parts for R99-01 FOR G6DS