VX-5-1C23 Omron, VX-5-1C23 Datasheet - Page 5

MINIATURE BASIC SWITCH

VX-5-1C23

Manufacturer Part Number
VX-5-1C23
Description
MINIATURE BASIC SWITCH
Manufacturer
Omron
Series
VXr
Type
Snap Actionr
Datasheets

Specifications of VX-5-1C23

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
5A @ 250VAC
Actuator Type
Round (Pin Plunger)
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .187" (4.7mm)
Operating Force
50gf
Contact Form
SPDT
Contact Rating
5 Amps
Actuator
Plunger, Pin
Body Style
Miniature
Current, Rating
5 A
Dielectric Strength
1500 VAC
Mounting Hole Size
3.1 mm
Number Of Poles
1
Operation
Snap Action
Termination
Quick Connect
Voltage, Rating
125/30 VAC/VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SW993
VX-5-1C23
VX51C23
VX
Short Hinge Lever Models
Hinge Lever Models
Long Hinge Lever Models
Simulated Roller Lever Models
OP
PT
OP
PT
3.4±0.15 dia.
PT
OP
PT
OP
2.8
3.4±0.15 dia.
3.1
2.8
3.4±0.15 dia.
3.4±0.15 dia.
3.5R
2.8
A
A
2.8
10.3±0.1
+0.13
−0.03
t = 0.5 (stainless-steel lever)
3.1
3.1
3.1
t = 0.5 (stainless-steel lever)
+0.13
+0.13
+0.13
10.3±0.1
−0.03
−0.03
10.3±0.1
−0.03
A
10.3±0.1
t = 0.5 (stainless-steel lever)
35.6±0.8
22.2±0.1
t = 0.5 (stainless-steel lever)
A
27.8
37.8±0.8
59.4±0.8
32.6±0.8
22.2±0.1
22.2±0.1
22.2±0.1
27.8
27.8
27.8
37.8±0.8
37.8±0.8
37.8±0.8
22.1
8.1
8.1
8.1
8.1
(10)
1.6
2.8
3.1
3.1
(10)
(10)
(10)
+0.13
−0.03
1.6
2.8
1.6
2.8
1.6
2.8
3.1
3.1
Three, solder terminals
+0.13
−0.03
15.9 18.8
+0.13
+0.13
−0.03
−0.03
dia. holes
Three, solder terminals
Three, solder terminals
Three, solder terminals
dia. holes
15.9 18.8
15.9 18.8
15.9 18.8
dia. holes
dia. holes
4.3
10.3
10.3
10.3
4.3
4.3
10.3
4.3
2.8
2.8
2.8
2.8
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Note:
OF max.
RF min.
PT max.
OT min.
MD max.
OP
OF max.
RF min.
PT max.
OT min.
MD max.
OP
OF max.
RF min.
PT max.
OT min.
MD max.
OP
Model
Model
Model
Model
The values indicated in parentheses
are reference values for cases when
the installation direction is such that
the lever weight is not applied to the
plunger.
0.49 N {50 gf}
0.04 N {4 gf} (reference value)
1.6 mm
0.8 mm
0.5 mm
15.2±0.5 mm
0.29 N {30 gf}
---
4.0 mm
1.6 mm
0.8 mm
0.20 N {20 gf}
---
9.0 mm
3.2 mm
2.0 mm
15.2±2.6 mm
0.29 N {30 gf}
0.02 N {2 gf}
4.0 mm
1.6 mm
0.8 mm
18.7±1.2 mm
15.2±1.2 mm
VX-51-1@3
VX-52-1@3
VX-53-1@3
VX-54-1@3
VX-011-1@3
VX-012-1@3
VX-013-1@3
VX-014-1@3
VX
5

Related parts for VX-5-1C23