XCKL510H7 SQUARE D, XCKL510H7 Datasheet

no-image

XCKL510H7

Manufacturer Part Number
XCKL510H7
Description
LIMIT SWITCH 240VAC 10AMP XCKL +OPTIONS
Manufacturer
SQUARE D
Datasheet
Product data sheet
Characteristics
Complementary
Apr 2, 2012
Switch actuation
Electrical connection
Contacts insulation form
Number of steps
Positive opening
Positive opening minimum force
Minimum force for tripping
Minimum actuation speed
Maximum actuation speed
Repeat accuracy
Contact code designation
[Ithe] conventional enclosed thermal current
[Ui] rated insulation voltage
Resistance across terminals
[Uimp] rated impulse withstand voltage
Short circuit protection
Electrical durability
Mechanical durability
Width
XCKL510H7
limit switch XCKL - metal end plunger - 1NC
+1NO - slow-break - 1/2NPT
Main
Range of product
Series name
Product or component
type
Device short name
Sensor design
Body type
Head type
Material
Body material
Fixing mode
Movement of operating
head
Type of operator
Type of approach
Cable entry
Number of poles
Contacts type and com-
position
Contacts operation
On end
Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Zb
1
With
45 N
15 N
6 m/min
0.5 m/s
0.05 mm on the tripping points with 1 million operating cycles
A300, AC-15 (Ue = 240 V, Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V, Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix
A
10 A AC
300 V conforming to CSA C22-2 No 14
300 V conforming to UL 508
500 V degree of pollution 3 conforming to IEC 60947-1
<= 25 mOhm conforming to IEC 60255-7 category 3
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
10 A by gG cartridge fuse
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate: <= 60
cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate: <= 60 cyc/
mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate: <= 60
cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
20000000 cycles
52 mm
OsiSense XC
Standard format
Limit switch
XCKL
-
Fixed
Plunger head
Metal
Zamak
By the body
Linear
Spring return plunger metal
Vertical approach 1 direction
3 entries tapped for 1/2" NPT cable gland
2
1 NC + 1 NO
Slow-break, break before make
1

Related parts for XCKL510H7

XCKL510H7 Summary of contents

Page 1

... Resistance across terminals [Uimp] rated impulse withstand voltage Short circuit protection Electrical durability Mechanical durability Width Apr 2, 2012 XCKL510H7 limit switch XCKL - metal end plunger - 1NC +1NO - slow-break - 1/2NPT Main Range of product OsiSense XC Series name Standard format ...

Page 2

Height Depth Environment Shock resistance Vibration resistance IP degree of protection IK degree of protection Class of protection against electric shock Ambient air temperature for operation Ambient air temperature for storage Protective treatment Product certifications Standards RoHS EUR status RoHS ...