XS2F-D421-D80-A Omron, XS2F-D421-D80-A Datasheet
XS2F-D421-D80-A
Specifications of XS2F-D421-D80-A
Related parts for XS2F-D421-D80-A
XS2F-D421-D80-A Summary of contents
Page 1
... D4CC-1050 rod Center D4CC-1060 roller lever Note: 1. Ask your OMRON representative for Information on approved models. 2. The meaning of suffix codes in the D4CC model numbers is different from that in the D4C model numbers. 3. Refer to the following table for cable plugs. (2) Actuator 01 : Pin plunger 02 : Roller plunger ...
Page 2
... Leakage Current for Switches with Indicators The leakage current and resistance of Switches with indicators are as follows: Item Model Voltage Leakage current Resistive value D4CC For DC Model XS2F-D421-C80-A XS2F-D421-D80-A XS2F-D421-G80-A XS2F-D421-J80-A Dog Mounting plate IP67 Mechanical 10,000,000 operations min. Electrical 200,000 operations min 125 VAC, resistive load) ...
Page 3
... Note: Colors in parentheses are the previous wire colors. Wire colors have been changed accompanying changes in standards. For AC Plug Pin No. Roller Center lever Spacer prevents the Switch from biting cut chips. O-ring (NBR) Built-in switch DC Switches (D4CC-30@@, 40@@) Without Operation Indicator Pin No.1 COM E With Operation Indicator (Lit when Not Actuated) *1 Pin No.1 COM E For DC Cable Pin No. ...
Page 4
... Dimensions and Operating Characteristics Switches Limit Switches The @ in each model number is replaced with the code expressing the rated load of the model. Refer to Model Number Legend. Pin Plunger 10 dia. D4CC-@001 stainless steel plunger 40 max. PT ± 25 0.1 OP 62.2 max. 57 max. 10.5 (2) Indicator 34 M12 × ...
Page 5
... Two, 5.1 dia. 0 holes Spot facing (2) 10.2 dia. depth 1.4 Indicator 34 M12 × 1 D4CC-@050 D4CC-@060 1.47 N 6.67 N --- 1.47 N 15° 10°±3° --- 50° --- 3° --- --- Cable length (L) For DC Model (m) XS2F-D421-C80-A 1 XS2F-D421-D80-A 2 XS2F-D421-G80-A 5 XS2F-D421-J80 1.5 . 1.5 5 ...
Page 6
... Special Mounting Plates (Limit Switches are not attached to the Plates.) D4C-P001 (For D4CC-@001) 34 (OP of WLD) D4C-P002 (For D4CC-@002) 44 (OP of WLD2) D4C-P020 (For D4CC-@024) 9.2 75 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Remarks There is no difference in mounting pitch between the Mounting Plate and the WL ...
Page 7
... Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. ...
Page 8
Plug Tightening • Connect the plug connector (B) to the connector threads (C) of the D4CC. Then firmly turn the plug connector by hand so that the connector threaded portion (C) will be completely covered by the plug connector (B) ...
Page 9
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...