88972250 Crouzet USA, 88972250 Datasheet - Page 76

XN06 MODBUS 8 WORD COM EXT

88972250

Manufacturer Part Number
88972250
Description
XN06 MODBUS 8 WORD COM EXT
Manufacturer
Crouzet USA
Series
Millenium 3, XN06r
Type
Extension, Sandwich - Communicationr
Datasheets

Specifications of 88972250

Voltage - Supply
24VDC Via Controller
Display Type
No Display
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Number Of I /o
-
Kit Contents
-
Analog Inputs
-
Lead Free Status / Rohs Status
 Details
Other names
88972250
966-1005
XB26
76
Part numbers
Type
XA03
XA04W
Accessories
Type
M3 SOFT
General characteristics
See General characteristics for the XA04 analogue extension on page 36, except for the adapted characteristics below:
Certifications
Conformity with the EMC directive
Inputs
Operating range
Input impedance
Maximum non destructive current/voltage
Resolution
Value of LSB
Input type
Conversion time
Sampling time
Accuracy at 25°C ambient temperature
Accuracy at 55°C ambient temperature
Temperature compensation
Isolation between analogue channel and
power supply
Dedicated isolated 24 V DC output for 4-20
mA sensor
Cable length
Protection against polarity inversions
Millenium 3 Custom
XA03: 3 Pt 100 temperature inputs in the same casing
XA04W: Mix of inputs in the same casing: Pt 100, pH,
ORP (Redox), Current (4 - 20 mA)
"Application-specific" examples:
- Regulation and measurement of (XA03)
- pH and Redox sensors for treating water in
swimming pools and fountains (XA04W)
Extensions compatible with any Millenium 3 Custom
expandable logic controller
For Pt100 probes, see page 54.
For pH and ORP probes, see page 78. The probes are
directly connected to the XA04W extension
"Application-specific" analogue extensions for XD10/XB10 and XD26/
Input
3 Pt 100 (-25
1 Pt 100 (0-50°C), 1 pH (0-14), 1 ORP
(0-1000mV), 1 current (4-20 mA)
Description
Multilingual programming software containing specific library functions (CD-ROM)
+125°C)
In accordance with
89/336/EEC:
EN (IEC) 61131-2
(Zone B)
EN (IEC) 61000-6-2,
EN (IEC) 61000-6-3,
Pt 100 (IP, IQ, IR)
-25°C, + 125°C
-
-
10 bits
0.15°C
Pt 100 probe
IEC 751
3-wire
Module cycle time
<1s
± 1°C
± 1°C
-
None
-
10 m max. with
shielded cable
88970800
UL, CSA,
-
EN (IEC) 61000-6-4
Supply
Via the 24 V
Via the 24 V
sensor)
88972805
UL & CSA
In accordance with
89/336/EEC:
EN (IEC) 61000-6-1
EN (IEC) 61000-6-3
Pt 100 (IP)
0-50°C
-
-
12 bits
0.012°C
Pt 100 probe
IEC 751
3-wire
Module cycle time
4s
± 0.8°C
± 0.8°C
-
None
-
3 m max. with
shielded cable
-
(1 dedicated output 24 V
XA03
controller
controller
pH (IQ)
0 - 14
> 10
-
12 bits
0.0034 pH
pH probe
Module cycle time
4s
± 0.05 pH
± 0.05 pH
No
Drift of 0.03 pH
from15 to 25°C
Drift of 0.15 pH
from 0 to 50°C
Isolated
-
3 m max. with
shielded cable
-
12
Ω
± 5% 0.6 W to supply the 4-20 mA
ORP (IR)
0 - 1000 mV
> 10
-
12 bits
0.24 mV
ORP probe
Module cycle time
4s
± 5 mV
± 5 mV
-
Isolated
-
3 m max. with
shielded cable
-
12
Ω
www.millenium3.crouzet.com
XA04W
4-20 mA (IS)
0 - 20 mA
10 Ω
30 mA
12 bits
4.9 μA
Common mode
Module cycle time
4s
± 0.1 mA
± 0.1 mA
-
Isolated
24 V
3 m max. with
shielded cable
Yes
Code
88970111
Code
88970800
88972805