EA3-B0-22-625-12A-DC Carling Technologies, EA3-B0-22-625-12A-DC Datasheet

CIRCUIT BREAKER

EA3-B0-22-625-12A-DC

Manufacturer Part Number
EA3-B0-22-625-12A-DC
Description
CIRCUIT BREAKER
Manufacturer
Carling Technologies
Datasheet

Specifications of EA3-B0-22-625-12A-DC

Product Type
Circuit Breakers
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
102
E-Series – General Specifications
Agency Certifications
UL Recognized
UL Standard 1077
UL Standard 508
UL Standard 1500
UL Listed
UL Standard 489
Electrical
Table A:
Breaker.
Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case Circuit
Component Recognition Program as
Protectors, Supplementary (Guide
QVNU2, File E75596)
Component Recognition Program as
Manual Motor Controls (Guide
NLRV2, File E135367)
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596) Ignition
Protection
Circuit Breakers, Molded Case
(Guide DIVQ, File E129899)
CSA Accepted
CSA Certified
TUV Certified
VDE Certified
Ideally suited for higher amperage applications. Available with
front and back mounting, screw terminals, stud terminals and
heavy duty box wire connectors for solid wire or a pressure
plate connector for stranded wire. Power selector device avail-
able, consult factory.
The E-Series is UL Listed and CSA Certified for Branch Circuit
protection which does not require a fuse backup. It is also UL
Recognized and CSA Certified as a Supplementary Protector
and as a Manual Motor Controller.
1-6 poles, .1 - 100 amps, up to 600 VAC or 125 VDC, with
choice of time delays and actuator colors.
Component Supplementary
Protector (Class 3215 30, File
047848 0 000)
CSA Standard C22.2 No. 235
Circuit Breaker Molded Case (Class
1432 01, File 093910), CSA
Standard C22.2 No. 5.1 - M
EN60934 under License No.
R72031056
EN60934, VDE 0642 under File No.
10537
www.carlingtech.com

Related parts for EA3-B0-22-625-12A-DC

EA3-B0-22-625-12A-DC Summary of contents

Page 1

E-Series – General Specifications Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors, Supplementary (Guide QVNU2, File E75596) UL Standard 508 Component Recognition Program as Manual Motor Controls (Guide NLRV2, File E135367) UL Standard 1500 Protectors, Supplementary ...

Page 2

Electrical Table B: Lists UL Recognized & CSA Accepted configurations & performance capabilities as a Component Supplementary Protector. Notes for Table B: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and ...

Page 3

E-Series – General Specifications Electrical Maximum Voltage 600VAC 50/60 Hz, 125VDC (See Table A) Current Ratings Standard current coils: 0.100, 0.250, 0.500, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 50.0, 60.0, 70.0 & 100 Amp. Auxiliary Switch Rating ...

Page 4

– Series Poles Actuator Circuit Auxiliary Switch 1 SERIES E 2 ACTUATOR Handle A Handle, one per pole 3 POLES 1 1 One 3 Three 2 Two 4 Four 4 CIRCUIT ...

Page 5

E-Series Handle UL Listed – Ordering Scheme – Series Poles Actuator Circuit 1 SERIES E 2 ACTUATOR Handle A Handle, one per pole 3 POLES 1 1 One 3 Three 2 Two ...

Page 6

Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 0-50 amps: 10-32 & M5 Studs .625 ±.062 /15.88 ±1.574 long. 51-120 amps: 1/4-20 & M6 Studs .750 ±.062 /19.05 ±1.574 long. www.carlingtech.com E-Series ...

Page 7

E-Series Handle (Back Connected) – Form & Fit Drawings Notes: 1 1/4 -20 stud terminal in Series Trip circuit configuration shown 3” min spacing must be provided between the circuit breaker arc venting area of back connected E-Series ...

Page 8

Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Box wire connector terminal in Series Trip circuit configuration shown. 4 Circuit breakers must be mounted on vertical surface. www.carlingtech.com E-Series Handle (Front Connected) ...

Related keywords