RK1-L2-4.5V PANASONIC EW, RK1-L2-4.5V Datasheet - Page 5

no-image

RK1-L2-4.5V

Manufacturer Part Number
RK1-L2-4.5V
Description
RK High Frequency Relay
Manufacturer
PANASONIC EW
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RK1-L2-4.5V
Manufacturer:
Panasonic
Quantity:
12 000
5. Electrical life test (0.01 A 24 V DC)
Sample: RK1-12V; No. of samples: n = 6
8.-(1) Influence of adjacent mounting
Sample: RK1-12V; No. of sample: n = 10
NOTES
1. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different. The nominal operating voltage
should be applied to the coil for more
than 20 ms to set/reset the latching type
relay.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or
malfunction.
3. External magnetic field
Since RK relays are highly sensitive
polarized relays, their characteristics will
be affected by a strong external magnetic
field. Avoid using the relay under that
condition.
4. Soldering and cleaning
1) Perform manual soldering under the
conditions below.
• Within 10 s at 260°C
• Within 3 s at 350°C
Preheat according to the following
conditions.
Soldering should be done at 260±5°C
500±5°F
Temperature
Time
12
10
–10
–10
8
6
4
2
0
10
10
0
0
within 6 s.
Inter-relay distance,
Pick-up voltage
Drop-out voltage
10
.197
No. of operations, ×10
Pick-up voltage
Drop-out voltage
5
120°C
Within 2 minute
662°F
500°F
248°F
20
.394
10
OFF condition
ON condition
(mm, inch)
OFF OFF
ON ON
or less
4
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
30
Max.
Min.
Max.
Min.
6. Ambient temperature characteristics
Sample: RK1-12V; No. of samples: n = 6
8.-(2) Influence of adjacent mounting
Sample: RK1-12V; No. of samples: n = 10
2) For automatic cleaning, the boiling
method is recommended. Avoid
ultrasonic cleaning which subjects the
relays to high frequency vibrations, which
may cause the contacts to stick. It is
recommended that alcoholic solvents be
used.
5. Conditions for operation, transport
and storage conditions
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
–40 to +70°C
(2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
(3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage:
(Avoid freezing
when used at
temperatures lower
than 0°C
–10
–10
10
10
10
0
0
0
–40
–40
–40
–40
32°F
Tolerance range
–20
–4
Temperature, °C
–40 to +158°F
85
Inter-relay distance,
Pick-up voltage
Drop-out voltage
5
+32
0
.197
0
(Avoid
condensation
when used at
temperatures higher
than 0°C
Humidity, %RH
5
20
68
–20
–40
40
20
32°F
104
40
°F
Pick-up voltage
Ambient temperature,
Drop-out voltage
140
.394
60
10
OFF condition
ON condition
(mm, inch)
OFF
OFF
+158
ON
ON
176
70
80
°C
°F
7. Contact resistance distribution (initial)
Sample: RK1-12V
No. of samples: n = 50 (50 × 2 contacts)
2) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the temperature
is lower than 0°C 32°F. This causes
problems such as sticking of movable
parts or operational time lags.
4) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
6. Latching relay
In order to assure proper operating
regardless of changes in the ambient
usage temperature and usage conditions,
nominal operating voltage should be
applied to the coil for more than 30 ms to
set/reset the latching type relay.
50
40
30
20
10
0
10
20
Contact resistance, mΩ
30
40
50
RK

Related parts for RK1-L2-4.5V