RP7SL024 Tyco Electronics, RP7SL024 Datasheet - Page 2

no-image

RP7SL024

Manufacturer Part Number
RP7SL024
Description
RP7SL024
Manufacturer
Tyco Electronics
Series
RP3SL, SCHRACKr
Datasheet

Specifications of RP7SL024

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
12A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
21.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
12A @ 250VAC
Control On Voltage (max)
18 VDC
Control Off Voltage (min)
2.4 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
6-1393231-6
Coil data, bistable coils
Rated coil voltage range
Operative range to IEC 61810
Reset voltage minimum / maximum, % of U
Minimum energization duration
Maximum energization duration
Coil versions, bistable coil
bistable, 1 coil
bistable, 2 coils
All figures are given for coil without preenergization, at ambient temperature +23°C, duty
factor 20%. Other coil voltages on request
Insulation
Dielectric strength coil-contact circuit
Clearance / creepage coil-contact circuit
Material group of insulation parts
Tracking index of relay base
Insulation to IEC 61810-1
Other data
Mechanical endurance DC-coil
Material
Environment
Processing
*
Accessories
For monostable and bistable 1 coil version, details see PCB accessories RT
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
code
)
A05
A12
A24
Coil
F12
F24
no socket available for bistable 2 coil version, see Accessories
Type of insulation coil-contact circuit
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
RoHS - Directive 2002/95/EC
Ambient temperature range RTII - flux proof
Vibration resistance (function), opening of closed cont. 20 g
Shock resistance (destruction)
Category of protection
Mounting
Mounting distance 12A / 16A
Resistance to soldering heat flux proof version
Relay weight
Packaging unit monostable, bistable 1 coil
voltage
Rated
VDC
12
24
12
24
5
open contact circuit
bistable coil
bistable 2 coils
Operate
voltage
open contact circuit
18.0
18.0
VDC
3.7
9.0
9.0
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
General Purpose Relays
Special Load PCB Relay RP 3 SL
RTIII - wash tight
wash tight version
voltage
Reset
16.7
18.0
VDC
3.6
8.7
9.0
rtd
compliant as per product date code 0404
70% / 110%
RTII - flux proof, RTIII - wash tight
220/0.5
820/0.5
Reset
c / W
39/0.5
1 coil
240 V
R1
3
Product specification
according to IEC 61810-1.
Product data, technical para -
me ters, test conditions and
micro disconnection
1 min at < 50% DF
pcb or on socket*
> 20x10
> 1x 10
W 0 / W 3 mm
270 °C / 10 s
20 / 500 pcs
-40...+70°C
-40...+35°C
W 8 / 8 mm
5...24 VDC
260°C / 5 s
reinforced
PTI 250 V
4000 V
2000 V
100 pcs
resistance
20 ms
250 V
100 g
18 g
115+10%
460+10%
105+15%
460+15%
IIIa
III
21+10%
1
Coil
6
6
c
cycles
cycles
rms
rms
75% / 120%
230 / 400 V
2 coils
)
2
Rated coil
(Continued)
power
1190
1252
1252
1371
1252
mW
processing information only
to be used together with the
'Definitions' section in the cat -
alogue or at schrackrelays.com
Circuit scheme for bistable 1 coil
PCB layout / terminal assignment
Bottom view on solder pins
Bistable versions:
Indicated contact position during or after coil
energization with reset voltage.
2-coil versions:
Operate A2, A3
Reset A1, A3
b) for 2 coil version only
in the ‘Schrack’ section.
Specifications subject to
change.
SCHRACK
S0163-CR
S0163-CS
2

Related parts for RP7SL024