3G3AX-CUSBM002-E Omron, 3G3AX-CUSBM002-E Datasheet - Page 14

no-image

3G3AX-CUSBM002-E

Manufacturer Part Number
3G3AX-CUSBM002-E
Description
USB Cable Of G5 Drive And PC
Manufacturer
Omron
Datasheet

Specifications of 3G3AX-CUSBM002-E

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
14
Main Circuit Terminals
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
+1, P/+2
P/+2, RB
P/+2, N/-
Standard Connections
Main power supply input terminal
Inverter output terminal
DC Reactor connection terminal
Braking Resistor connection terminal
Regenerative Braking unit connection terminal
Ground terminal
Connect the input AC power supply.
Drives with 1-phase 200 V input power supply use only terminals L1 and N.
Used to connect a 3-phase motor.
Remove the shorting bar between terminals +1 and p/+2, and connect the optional DC reactor.
Connect optional braking resistors. (If a braking torque is required.)
Connect optional regenerative braking units. (When braking torque is required or the built-in braking circuit is not sufficient.)
This a ground terminal. Connect this terminal to the ground. Provide Class D grounding for 200 V class models, and
class C grounding for 400 V class models. On 200 V class models of 3.7 kW (5 HP) or below and 400 V class models of
4.0 kW (5 HP) or below, the ground terminal is located on the cooling fin.