Using Digital Operator
1. Setting the Maximum output frequency
26
(It continues in upper right.)
dk0k0k1
ak-k-k-
ak0k0k1
Power ON
0.0
Multi-functional Compact Inverters SYSDRIVE
Press
Press
Press
Press
key.
key.
(1) 0.0 or the value previously
(2) Function code appears.
(3) A --- appears.
(4) A001 or the code number set
until A --- appears.
until A --- appears.
monitored is displayed.
in the end of last setting is
displayed.
• To run the motor, go back to monitor mode or basic setting
• Pressing
MX
mode.
ak0k0k4
ak0k0k4
1k0k0.
Series
5k0.
Press
Press
Press
key for a while and back to d001.
key.
key to store the values.
(5) A004 appears.
(6) Preset value is displayed.
(7) Newly set value is displayed.
(8) Returns to A004 and the
to set desired value.
setting is complete.