Specifications of CPM2C-S100C-DRT

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CPM2C-S1 0C-DRT
Item
Data Memory
DeviceNet slave
functions
Basic interrupt functions
High-speed counter
functions
Quick-response inputs
Pulse outputs
Synchronized pulse control
Input time constant
(ON response time = OFF response time)
Clock function
Communications
functions
Memory protection
Memory backup
Self-diagnostic functions
Program checks
Programming Devices
General and Performance Specifications (continued)
Read/Write
Read-only
PC Setup
Interrupt inputs
Scheduled
interrupts
High-speed
counters
Counter interrupts 1 interrupt (set value comparison or set-value range comparison)
Interrupt inputs
(counter mode)
Count-up
interrupts
Peripheral port:
RS-232C port:
Programming
Console
Ladder Support
Software (V3/V6)
SYSMAC Support
Software (V1.1)
For more information, contact an Omron representative at 1-800-55-OMRON
Specifications
2,048 words (DM 0000 to DM 2047)
The Error Log is contained in DM 2000 to DM 2021
456 words (DM 6144 to DM 6599)
56 words (DM 6600 to DM 6655)
DeviceNet Remote I/O Link
Explicit Message Communications
2 interrupts (used for both counter mode interrupt inputs and the quick-response inputs)
1 interrupt
1 counter (20 kHz single-phase or 5 kHz two-phase)
2 interrupts (used for both external interrupt inputs and quick-response inputs)
2 interrupts (used for both external interrupt inputs and quick-response inputs)
2 inputs (used for both external interrupt inputs and counter mode interrupt inputs)
Minimum input pulse width: 50 s max.
Shared by input interrupts and input interrupt counter mode
2 points with acceleration/deceleration, 10 Hz to 10 kHz each, and no
direction control; 1 point with trapezoid acceleration/deceleration, 10 Hz to 10 kHz,
and direction control; 2 points with variable duty-ratio outputs
1 point
Can be set for CPU inputs and Expansion Unit inputs only
(1, 2, 3, 5, 10, 20, 40, or 80 ms)
Equipped with clock (built-in RTC)
Supports Host Link, peripheral bus, no-protocol, or Programming Console connections
Supports Host Link, no-protocol, 1:1 Link, or 1:1 NT Link connections
HR area, AR area, program contents, DM area contents, and counter values
maintained during power interruptions
Non-volatile (flash) memory:
Program, read-only DM area and PC Setup
Lithium battery (2-year)
DM area, HR area, AR area and counter values are backed up
CPU errors (watchdog timer), memory errors, communications errors, setting errors,
battery errors, and expansion I/O bus errors
No END instruction, programming errors (checked when operation is started)
C200H-PRO27, CQM1-PRO01, or CQM1H-PRO01
IBM PC/AT or compatible
IBM PC/AT or compatible
Uses up to 1,024 I/O points in the I/O Link.
Any PC data area can be accessed from the master.
CPM2C-S1 0C-DRT