Functions of General-purpose Slaves and Environment-resistive Slaves
4-3-5
Function Overview
66
Total ON Time Monitor
Note
5. After checking that the setting for the monitor value is reflected in the Edit
6. Click the OK Button.
The total ON time for each I/O contact can be calculated (unit: s) and
recorded in the Slave. (The Configurator or explicit messages can be used to
read the information.)
The monitor value can be set in the Slave, and when the set number of opera-
tions is reached, the Connected Component Maintenance Flag in the Status
Area is turned ON. (The Configurator or explicit messages can be used to
read the status of the Connected Component Maintenance Flag.)
1. The Total ON Time Monitor and Contact Operation Counter cannot be
2. The Total ON Time Monitor operates when the I/O power is ON only.
3. The Total ON Time Monitor checks approximately every second whether
• Measured time: 0 to 4294967295 s (stored data: 00000000 to FFFFFFFF
• Measuring unit: s
Value field, and then click the OK Button.
Device Parameters Window, select the General Tab and click the Down-
load Button.
Hex)
used at the same time for a single contact. Select the function to be used
under the Detection Mode heading.
the connected devices are ON.
If the total ON time is calculated for ON times of less than a second, the
measurement may not be accurate.
Recorded in
the Slave
Sensor
Total ON time
Slave
Connected
device
Total ON time
I/O power
ON
OFF
Section 4-3