G2R-2-T130 AC24 Omron, G2R-2-T130 AC24 Datasheet - Page 3

no-image

G2R-2-T130 AC24

Manufacturer Part Number
G2R-2-T130 AC24
Description
POWER PCB RELAY
Manufacturer
Omron
Series
G2Rr
Datasheet

Specifications of G2R-2-T130 AC24

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
37.5mA
Coil Voltage
24VAC
Turn On Voltage (max)
19.2 VAC
Turn Off Voltage (min)
7.2 VAC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
19.2 VAC
Control Off Voltage (min)
7.2 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-2-T130AC24
G2R2T130AC24
G2R
Specifications
I
Note:
Note:
High-sensitivity Relays
Note:
Rated voltage
Rated current
Coil resistance
Coil inductance
(H) (ref. value)
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated voltage
Rated current (50/60 Hz)
Coil resistance
Coil inductance
(H) (ref. value)
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated voltage
Rated current (50/60 Hz)
(see note 1.)
Coil resistance (see note 1.)
Coil inductance
(H) (ref. value)
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Coil Ratings
1. Rated voltage of bifurcated crossbar contact type: 100/(110) VAC, 200/(220) VAC, 230 VAC (Approx. 0.7 VA at 60 Hz)
2. Depending on the type of Relay, some Relays do not have coil specifications. Contact your OMRON representative for more
Rated voltage of bifurcated crossbar contact type: 12 VDC, 24 VDC
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
2. LEDs are used for the built-in operation indicator. For models equipped with these indications, the VAC rated current must be
3. Operating characteristics are measured at a coil temperature of 23°C.
details.
or ±10% (DC coil resistance).
increased by approximately 1 mA; the VDC rated current, by approximately 4 mA.
50 Hz
60 Hz
Armature OFF
Armature ON
Armature OFF
Armature ON
Armature OFF
Armature ON
12 VAC
93 mA
75 mA
65
0.19
0.39
80% max. of rated voltage
30% min. of rated voltage
140% of rated voltage (at 23 C)
Approx. 0.9 VA at 60 Hz (approx. 0.7 VA at 60 Hz)
5 VDC
106 mA
47
0.20
0.39
70% max. of rated voltage
15% min. of rated voltage
170% of rated voltage (at 23 C)
Approx. 0.53 W
5 VDC
71.4 mA
70
0.37
0.75
70% max. of rated voltage
15% min. of rated voltage
170% of rated voltage (at 23 C)
Approx. 0.36 W
24 VAC
46.5 mA
37.5 mA
260
0.81
1.55
6 VDC
88.2 mA
68
0.28
0.55
6 VDC
60 mA
100
0.53
1.07
100/
(110) VAC
11 mA
9/
(10.6) mA
4,600
13.34
26.84
12 VDC
43.6 mA
275
1.15
2.29
120 VAC
9.3 mA
7.5 mA
6,500
21
42
12 VDC
30 mA
400
2.14
4.27
200/ (220)
VAC
5.5 (4.0)
mA
4.5 (5.3)
mA
20,200
(25,000)
51.3
102
24 VDC
21.8 mA
1,100
4.27
8.55
24 VDC
15 mA
1,600
7.80
15.60
220 VAC
5.1 mA
4.1 mA
25,000
57.5
117
48 VDC
11.5 mA
4,170
13.86
27.71
+15%
230 VAC
4.7 (3.7) mA 4.7 mA
3.8 (3.1) mA 3.8 mA
26,850
(30,000)
62
124
/
–20%
48 VDC
7.5 mA
6,400
31.20
62.40
(AC rated current)
100 VDC
5.3 mA
18,860
67.2
93.2
240 VAC
30,000
65.5
131
G2R
3

Related parts for G2R-2-T130 AC24