System Maintenance
6-11-5 Displaying and Printing the Alarm History Record
196
Example Print-out
All of the recorded data is printed out in the same order as on the currently
displayed screen.
Example:
Sort by occurrence, from oldest record
The alarm history record function is a function that continually monitors, dur-
ing operation, the status of bits at the host designated in advance with a bit
memory table, and records the time when these bits come ON, and the num-
ber of times they come ON.
The record data can be displayed, and printed out at a printer connected to
the NT631/NT631C by operation from the System Menu.
This section explains how to display and print out the alarm history record
data recorded in the NT631/NT631C.
Note that there are two display methods sort by occurrence (ON time order)
and sort by frequency (order of number of times the bits have come ON).
No. Scrn
1
2
3
4
1
2
8
2000 98/01/13
YY/MM/DD HH:MM Comment
98/01/12
98/01/12
98/01/13
10:21
11:53
09:35
14:22
Coolant Error
Motor Error
Compressor Error
Emergency Stop
Press Quit.
The NT631/NT631C returns to the DISPLAY
HISTORY MENU screen.
If necessary, select the next or previous
screen by pressing [↓] (next screen) or
[↑] (previous screen).
If required, press Prt. to print the display
history record data.
The example screen to the left shows a
display for the sort by occurrence
method (from oldest record).