V-21-1C6 Omron, V-21-1C6 Datasheet - Page 5

MINIATURE BASIC SWITCH

V-21-1C6

Manufacturer Part Number
V-21-1C6
Description
MINIATURE BASIC SWITCH
Manufacturer
Omron
Series
Vr
Type
Snap Actionr
Datasheets

Specifications of V-21-1C6

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
21A @ 250VAC
Actuator Type
Round (Pin Plunger)
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .250" (6.3mm)
Operating Force
400gf
Contact Form
SPDT
Contact Rating
21 Amps at 250 VoltsAC
Actuator
Plunger, Pin
Ingress Protection
IP40
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
V211C6
V
Note:
Consult your OMRON sales representative for specific models with standard approvals.
UL1054 (File No. E41515)/CSA C22.2 No. 55 (File No. LR21642)
EN61058-01 (File No. 40025231, VDE approval)
Testing conditions: 5E4 (50,000 operations), for models of V-21: T80 (0°C to 80°C), for models of V-16: T105 (0°C to 105°C)
Operating speed
Operating frequency
Insulation resistance
Contact resistance
(initial value)
Dielectric strength
(see note 2)
Vibration resistance
(see note 3)
Shock resistance
(see note 3)
Durability
(see note 4)
Degree of protection
Degree of protection against
electric shock
Proof tracking index (PTI)
Ambient operating tempera-
ture
Ambient operating humidity
Weight
125 VAC
250 VAC
125 VDC
250 VDC
250 VAC
Characteristics
Approved Standards
Rated voltage
Rated voltage
1. The data given above are initial values.
2. The dielectric strength values shown in the table are for models with a Separator.
3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models,
4. For testing conditions, contact your OMRON sales representative.
they apply at the total travel position.
21 A, 1/2 HP
0.6 A
0.3 A
20 (4) A
0.1 mm to 1 m/s (pin plunger models)
Mechanical:600 operations/min max. (pin plunger models)
Electrical:60 operations/min max.
100 MΩ min. (at 500 VDC)
15 mΩ max.
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
V-21 and V-16 models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and
ground, and between each terminal and non-current-carrying metal parts
V-15 and V-10 models: 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and
ground, and between each terminal and non-current-carrying metal parts
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: V-21/V-16/V-15: 300 m/s
Mechanical: 50,000,000 operations min. (60 operations/min)
Electrical:
IEC IP40
Class I
175
–25°C to 80°C (at ambient humidity of 60% max.) (with no icing or condensation)
–25°C to 150°C for heat-resistive model (at ambient humidity of 60% max.) (with no icing or conden-
sation)
85% max. (for 5°C to 35°C)
Approx. 6.2 g (pin plunger models)
V-21
V-21
V-21/V-16/V-15: 100,000 operations min. (30 operations/min)
V-10:
V-10:
16 A, 1/2 HP
0.6 A
0.3 A
16 (4) A
2
{approx. 100G} max.
200 m/s
(V-15 heat resistive: 20,000 operation min. (30 operations/min))
300,000 operations min. (30 operations/min)
(V-10 heat resistive: 50,000 operation min. (30 operations/min))
V-16
V-16
2
2
{approx. 30G} max.
{approx. 20G} max.
15 A, 1/2 HP
0.6 A
0.3 A
V-15
10 A, 1/3 HP
0.6 A
0.3 A
V-10
V
5

Related parts for V-21-1C6