ZEN-10C2AR-A-V2 Omron, ZEN-10C2AR-A-V2 Datasheet - Page 52

100/240 VAC 6 IN, 4 OUT

ZEN-10C2AR-A-V2

Manufacturer Part Number
ZEN-10C2AR-A-V2
Description
100/240 VAC 6 IN, 4 OUT
Manufacturer
Omron
Series
ZEN V2r
Type
Expandabler

Specifications of ZEN-10C2AR-A-V2

Voltage - Supply
100 ~ 240VAC
Number Of I /o
6 Input, 4 Output
Display Type
LED
Output Type
Relay
Voltage Rating
100 V to 240 V
Input Type
AC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Kit Contents
-
Analog Inputs
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Z2680
ZEN10C2ARAV2
Memory Areas
1-4
I/O, Work, and Internal Holding Bits
CPU Unit
input bits
Expansion
I/O Unit
input bits
Button
input bits
Analog
comparator
bits
Compara-
tor bits
8-Digit
comparator
bits
CPU Unit
output bits
Expansion
I/O Unit
output bits
Work bits
Holding
bits
Name
Note
Memory Areas
I
X
B
A
P
G
Q
Y
M
H
Type
addresses
0 to 5
0 to b
0 to b
0 to 7
0 to 3
0 to f
0 to 3
0 to 3
0 to 7
0 to b
0 to f
0 to f
1.
2.
Bit
Output bit Q3 of CPU Units with communications cannot be
output externally. It can be used as a work bit.
The following additional functions can be selected for bit outputs.
Execution condition
bits
6
12
12
8
4
16
4
4
8
12
16
16
No.
of
CPU Units
with 10 I/O pts
CPU Units
with 20 I/O pts
Reflect the ON/OFF status of the input
devices connected to the Expansion
I/O Unit input terminals.
Turn ON when the operation buttons
are pressed in RUN mode. Cannot be
used for LED-type CPU Units.
Output the comparison result for
analog inputs. Can only be used for
models with a 24-VDC power supply.
Compare the present value of timers
(T), holding timers (#), and counters
(C), and outputs the comparison result.
Compare the present value of 8-digit
counters (F) with a constant and
outputs the comparison result
CPU Units
with 10 I/O pts
(See note 1.)
CPU Units
with 20 I/O pts
Output the ON/OFF status of the output
bits to the outputs devices connected to
the Expansion I/O Unit.
Can only be used within the program.
Cannot output to an external device.
Same as for work bits however the
holding bits maintain ON/OFF status
when power is turned OFF.
Additional function ([, S, R, A)
Bit type
Function
Reflect the ON/OFF
status of the input
devices connected to
the CPU Unit input
terminals.
Output the ON/OFF
status of the output
bits to the outputs
devices connected to
the CPU Unit.
Bit address
N.O./N.C.
inputs
N.O./N.C.
inputs
Outputs
(See note
2.)
programs
Ladder
Section 1-4
32
32
99
87
91
94
32
32
-
-
Page
29

Related parts for ZEN-10C2AR-A-V2