ZFV-XMF2 Omron, ZFV-XMF2 Datasheet - Page 2

no-image

ZFV-XMF2

Manufacturer Part Number
ZFV-XMF2
Description
ZFV Sensor Bracket
Manufacturer
Omron
Datasheet

Specifications of ZFV-XMF2

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Cables
*1.
*2.
Specifications
Controller
2
Camera
Cable
Camera
Extension
Cable
Parallel I/O Cable
RS-232C Cable
RS-422 Cable
Monitor Cable
Item
Number of connected cameras
Connectable camera
Processing resolution
Display
Exter-
nal I/F
Operation I/F
Main
functions
Support
Menu language
Ratings
It is necessary for ZFX-S and ZFX-SC. ZFX-SR_/SC_ is a cable drawing out
type, it doesn't use it.
Up to two camera extension cables can be connected to the camera cable as
long as the total cable length between the controller and the camera does not
exceed 19 m.
*1
Parallel Interface
Serial Interface
Network
communications
Monitor output
Memory card I/F
Number of registered banks
Number of setup items
Measurement
items
Postion correction
Image memory function
Type
Normal type
Robot cable type 3m
Normal type
Robot cable type 3m
LCD monitor
Indicator
Input
Output
Circuit type
USB2.0
RS-232C
RS-422
Ethernet
Shape inspection
Size inspection
Edge inspection
Brightness/color inspection
Application-based
inspection
Code reading
Power supply voltage
Current consumption
Insulation resistance
Dielectric strength
3m, 8m
3m
8m
2m, 5m
2m
2m
2m, 5m
Cable
length
ZFX-VS
ZFX-VSR
ZFX-XC3A
ZFX-XC8A
ZFX-XC3AR
ZFX-VP
ZFX-XPT2A
ZFX-XPT2B
FZ-VM
Model
*2
*2
*2
1
ZFX-SR_/SC_/S/SC
When ZFX-SR_/SC_ is connected:464 (H) x464 (V)
When ZFX-S/SC is connected:608 (H) x464 (V)
3.5" TFT color LCD (320 x 240 pixels)
"Measuring" indicator (color: green): RUN
Trigger indicator (color: blue): ENABLE
Judgment indicator (color: orange): OUTPUT
Error indicator (color: red): ERROR
12 points (RESET, DSA, DI0 to 8, TRIG)
22 points (OR, ERROR, RUN, ENABLE, GATE, STGOUT0, DO0 to 15)
NPN
1 port, FULL SPEED, MINI-B connector
1 port, max. 115200 bps (cannot be used simultaneously with RS-422 interface)
1 port, max. 115200 bps (cannot be used simultaneously with RS-232C interface)
1 port, 100BASE-TX/10BASE-T
Analog RGB output, 1 ch (resolution VGA: 640 x 480)
SD card slot 1 ch
Touch panel, key operation, console connection
32 banks
32 items/1 bank
Pattern search, sensitive search
Area
Position, width, count
Brightness, HUE
Defects
Barcode (WPC(JAN/EAN/UPC), Code 39, Codebar (NW-7),
ITF (Interleaved 2 of 5), Code 93, Code 128, GS1-128, GS1 Databar,
Pharmacode)
Datamatrix (ECC200, QR Code,MicroQR Code,PDF417,MicroPDF417,
Maxi Code, AZtec Code, Codablock)
1 model search, 2 model search, position, area
Max. 100 images
Japanese/English (can be switched)
21.6 to 26.4 VDC (including ripple)
1.5 A max.
Across all lead wires and controller case: 20 M (by 250 V megger)
Across all lead wires and controller case, 1000 VAC, 50/60 Hz, 1 min
Accessories
*1.
*2.
Console
LCD Monitor
Panel Mount Adapters
Optional
Lighting
CCTV Lenses/Extension Tubes
External Lighting
Strobe Controller
ZFX-C10-CD
It is possible to ZFX-SC50 and ZFX-SC90 use it.
It is possible to ZFX-S and ZFX-SC use it. It uses it so that the controller may
control an external lighting.
*1
Type
*2
bar lighting
bar double-
lighting
bar low-angle
lighting
light source for
through beam
PNP
ZFX-KP (2m / 5m)
FZ-M08
ZFX-XPM
ZFV-LTL01
ZFV-LTL02
ZFV-LTL04
ZFV-LTF01
3Z4S-LE series
3Z4S-LT series
Manufactured by
MORITEX Corporation
3Z4S-LT
MLEK-C100E1TSX
ZFX-C15-CD
Vision Systems
Model

Related parts for ZFV-XMF2