Specifications of A22E-L-11

Circuit
DPST (1-NO, 1-NC)
Switch Function
On-Off, Off-On
Contact Rating @ Voltage
10A @ 110VAC
Actuator Type
Mushroom Button
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Contact Form
SPST - NC-NO
Contact Rating
10 Amps at 110 Volts
Actuator
Round, Large
Mounting Style
Through Hole
Illumination
Not Illuminated
Body Shape
Square
Dielectric Strength
2500 Volts
Features
Easy mounting and removal of switch unit
Insulation Resistance
100 MOhms
Mounting Angle
Straight
Water / Moisture Rating
IP65
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Illumination Type, Color
-
Illumination Voltage (nominal)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
A22EL11
Install in 22-dia. or 25-dia. Panel Cutout
Model Number Structure
Model Number Legend (Completely Assembled)
2. Head Size
1. Lighted/Non-lighted
* Lighted Emergency Stop
• Direct opening mechanism to open the circuit when the contact
• Safety lock mechanism prevents operating errors.
• Easy mounting and removal of Switch Blocks using a lever.
• Mount three Switch Units in series to improve wiring efficiency
• Finger protection mechanism on Switch Unit provided as a
• Install using either round, or forked crimp terminals.
• Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models)
• A lock plate is provided as a standard feature to ensure that the
Code
Code
MP
LP
S
M
L
SK
MK
None Non-lighted
L
Emergency Stop Switch (22-dia./25-dia.)
A22E
welds
(with non-lighted Switch Units, three Units can be mounted for
multiple contacts).
standard feature.
control box and switch are not easily separated.
Switches are available only
for the medium (M).
push-lock turn-reset models.
Be sure to read the precautions for all pushbutton switches
in the Pushbutton Switches Group Catalog (Cat. No. X032),
as well as the “Safety Precautions” on page 16.
Lighted *
Medium
40 dia.
Large
60 dia.
Small
30 dia.
Medium
40 dia.
Large
60 dia.
Small
30 dia.
Medium
40 dia.
Size
Description
.
Push-pull
Push-lock turn-reset
Push-lock key reset
Description
3. Light Source
Equipped with 24-VAC/DC LED.
Without Voltage Reduction Unit
Code
Code
None Non-lighted
6A
12A
24A
With Voltage Reduction Unit
T1
T2
Description
LED
Description
LED
L
Operating Voltage
6 VAC/VDC
12 VAC/VDC
24 VAC/VDC
Operating Voltage
100 VAC
200 VAC
M
---
24A
4. Contacts
Code
........ Shipped as a set which includes the Operation Unit, Lamp
01
11
02
12
03
01
(lighted models only), and Switch.
SPST-NC
SPST-NO + SPST-NC
DPST-NC
DPST-NC + SPST-NO
TPST-NC
Description
5. Configuration
Code
None
B
Switch only
Switch with Integrated
Control Box
Configuration
CSM_A22E_DS_E_9_1
1

Related parts for A22E-L-11

A22E-L-11 Summary of contents

Page 1

... Switch. L 24A Contacts Code Description Description Operating Voltage 01 SPST-NC --- 11 SPST-NO + SPST-NC LED 6 VAC/VDC 02 DPST-NC 12 VAC/VDC DPST-NC + SPST- VAC/VDC 03 TPST-NC Description Operating Voltage LED 100 VAC 200 VAC CSM_A22E_DS_E_9_1 5. Configuration Code Configuration None Switch only Switch with Integrated B Control Box 1 ...

Page 2

... A22E-S-02 * DPST-NC A22E-S12 * DPST-NC + SPST-NO A22E-S-03 * TPST-NC A22E-M-01 * SPST-NC A22E-M-11 * SPST-NO/SPST-NC A22E-M-02 * DPST-NC A22E-M-12 * DPST-NC + SPST-NO A22E-M-03 * TPST-NC A22E-L-01 * SPST-NC A22E-L-11 * SPST-NO/SPST-NC A22E-L-02 * DPST-NC SPST-NC A22E-SK-01 SPST-NO/SPST-NC A22E-SK-11 DPST-NC A22E-SK-02 SPST-NC A22E-MK-01 SPST-NO/SPST-NC A22E-MK-11 DPST-NC A22E-MK-02 Set Model Contact Configuration A22E-M-01-EMO * ...

Page 3

... Turn-reset with Voltage Reduction Unit SPST-NO/SPST-NC A22E DPST-NC * Models with Korean S-mark certification. Note: The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.) Switch with Integrated Control Box Appearance Contact configuration SPST-NC SPST-NO/SPST-NC DPST-NC * Models with Korean S-mark certification. ...

Page 4

... Units. These can also be used as inventory for maintenance parts. Non-lighted Operation Unit *1 Switch *2 *1.The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.) * three Switch Units can be mounted for multiple contacts. Lighted (without Voltage Reduction Unit) Operation Unit *1 ...

Page 5

... A22E-SK Push-lock, key-reset (push-lock, turn-reset) Lighted Sealing capability Function Size A22EL-M Push-lock, turn-reset Note: The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.) IP65 oil-resistant models Small (30 dia.) Medium (40 dia.) A22E-MP --- A22E-M A22E-MK IP65 Medium (40 dia.) A22E Large (60 dia ...

Page 6

... Note: When using with a Voltage Reduction Unit, use the A22-24AR. Model A22-6AR A22-12AR A22-24AR Model A22-5 A22-12 A22-24 A22-H1 Non-lighted Momentary Model A22-01M A22-02M Lighted (110 VAC) Momentary Model A22L-01M-T1 A22L-02M-T1 A22E Lighted Momentary Model A22L-01M A22L-11M A22L-02M Lighted (220 VAC) Momentary Model A22L-01M-T2 A22L-11M-T2 A22L-02M-T2 6 ...

Page 7

... A22Z-B101Y (for emergency stop) --- A22K-K Rounded shape A22Z-3360 --- A22Z-3901 --- A22Z-3905 A22E Remarks Provided as standard. Order Switch Blocks only when adding or replacing them. Used when changing the lighting method. Provided as standard. Order Mounting Latches only when mounting Switch Blocks or Lamp Sockets that are purchased individually. ...

Page 8

... EMERGENCY STOP come as a set. Use with an A22E Emergency Stop Switch. (for emergency stop) *1*2 Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI S2 compatibility. Use with an A22E with EMS indication. (for emergency stop) *2 SEMI-S2/SEMATECH Application Guide for SEMI S2-compatible Shroud. (for emergency shutoff) *1*2 Use together with an A22E Emergency Stop Switch ...

Page 9

... The degree of protection from the front of the panel. Structure and Nomenclature Operation Unit Color: Red Non-lighted Lighted Note: The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.) Lamp Light source • LED Lamp • Incandescent Lamp ⎫ ...

Page 10

... Lighted Models A22EL-M Medium Push-lock, Turn-reset (40-dia.) 1.5 40 dia. 6.5 18.5 0.5 32 Note: The Operation Unit of A22E exept models with EMO/EMS indication is red. (The engraved mark is not white.) A22E-LP Large Push-pull (60-dia.) 34 1.8 0.5 5.9 54.7 A22E-M Medium Push-lock, Turn-reset (40-dia ...

Page 11

... Ring A22Z-R25 22.2 dia. Material: NBR (black) 2.8 Incandescent Lamp A22-5, 12, 24, H1 BA9S/13 Cable Draw-out Hole (Top View) Two, 21 dia. Side lead draw-out hole (Side lead draw-out hole) A22E 6.1 20.5 3.8 34.7 dia. 2.8 22.2 dia. 30 dia. 4 A22Z-3466-2 (60 dia ...

Page 12

... Panel Cutout Dimensions +0.4 22.3 0 24.2± 0.2 +0.1 1.7R 0 Allowable panel thickness Switch Unit A22E-M Panel EMERGENCY OFF inscription plate (t=1) Rubber packing (t=0.5) Sunken section, 0.2 Switch guard Rubber packing (t=0.5) Mounting panel Locking ring Mounting a 2-pole Switch Unit * ...

Page 13

... Reduction Unit Lighted with Voltage Reduction Unit 2 X2 Note: The above terminal connection diagrams are examples for SPST-NO + SPST-NC and DPST-NC. +0.5 25 dia. 0 Lighted 10 10 16.7 Switch Blocks Lamp Socket Terminal connection (BOTTOM VIEW) DPST-NC DPST-NC + SPST- Switch Blocks 22 TPST- A22E ...

Page 14

... Ring (A22Z-R25) 0.5 22.3 dia. 25 dia. Screwdriver 25 dia. 22.3 dia. Lock Ring Mounting Ring A22E Panel Rubber washer Mounting Ring Projecting part Lock Ring Lock Ring Panel 2. When the panel cutout dimension is 30 dia., use resin attachment A22Z-A30. Since it is not attached to the main body, order separately ...

Page 15

... Mounting Ring inside the box. 2. Pass the tightening cap through the cable, insert the cable into the connector, and tighten the tightening cap to secure the cable. Rubber washer Mounting RIng Connector Cable diameter Inside Outside dia. Box dia. A22E Tightening cap Cable Connector A22Z-3500-1 A22Z-3500-2 15 ...

Page 16

... Press the hole on the Lock Plate onto the protrusion on the Mounting Latch until it clicks into place. Lever Operation Unit Mounting Latch A22E Wiring • Loosen the terminal screw from the Switch Unit until it completely comes off the groove, insert a screwdriver as shown in the following figure, then push up the washer in the direction indicated by the arrow to temporarily secure it ...

Page 17

... Also, most Switches are made from resin and will be damaged if they come into contact with sharp objects. Particularly scratches on the Operation Unit may create visual and operational obtrusions. Handle the Switches with care, and do not throw or drop them. A22E ) (conforming to JIS C5003). 60 − ...

Page 18

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords