A22Z3360 Omron, A22Z3360 Datasheet - Page 13
A22Z3360
Manufacturer Part Number
A22Z3360
Description
RND LOCK FITTING
Manufacturer
Omron
Type
Lock Fittingr
Datasheet
1.A22Z3360.pdf
(29 pages)
Specifications of A22Z3360
Switch Type
Push Button Switch
Lead Free Status / Rohs Status
Compliant
Specifications
Approved Standard Ratings
U L , cU L (File No. E415 1 5 )
6 A at 220 VAC, 10 A at 110 VAC
Note: Only Switch Blocks and Lamp Sockets are recognized by UL.
EN6 0 9 4 7 - 5 - 1 (Low Voltage Directive)
3 A at 220 VAC
CCC (GB140 4 8 . 5 )
3 A at 240 VAC, 1.5 A at 24 VDC
Ratings
Contacts (Standard Load)
Note: 1. The above ratings were obtained by conducting tests under the
Contacts (Microload)
Rated applicable load
Minimum applicable load
(Standard
Contacts
Load)
10A
2. Minimum applicable load: 10 mA at 5 VDC
Refer to Page 10 for the model numbers.
following conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5% RH
(3) Operating frequency: 20 operations/minute
24 VAC
110 VAC
220 VAC
380 VAC
440 VAC
24 VDC
110 VDC
220 VDC
380 VDC
voltage
Rated
tive load
Induc-
50 mA at 24 VDC (Resistive load)
1 mA at 5 VDC
10
---
5
3
2
1
tive load
Rated current (A)
Resis-
10
10
---
6
3
2
tive load
Induc-
1.5
0.5
0.2
0.1
---
tive load
Resis-
0.6
0.2
---
10
2
LED Indicators
Incandescent Lamp
Voltage-reduction Lighting
6 VAC/VDC
12 VAC/VDC
24 VAC/VDC
6 VAC/VDC
14 VAC/VDC
28 VAC/VDC
110 VAC
220 VAC
Rated voltage
Rated voltage
voltage
Rated
current
Rated
8 mA
Rated current
Rated current
200 mA
80 mA
40 mA
8 mA
Operating voltage
(190 to 230 V)
(95 to 115 V)
100 VAC
200 VAC
Operating voltage
Operating voltage
12 VAC/VDC±5%
24 VAC/VDC±5%
6 VAC/VDC±5%
Applicable lamp
(BA9 S /Base: 13)
12 V
24 V
5 V
(A22-24A
LED Lamp
A22
@
)
13