D4A-E00 Omron, D4A-E00 Datasheet

LIMIT SWITCH LEVER

D4A-E00

Manufacturer Part Number
D4A-E00
Description
LIMIT SWITCH LEVER
Manufacturer
Omron
Type
Fork Lever Lockr
Series
D4Ar
Datasheet

Specifications of D4A-E00

Switch Type
Limit Switch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D4AE00
The Limit Switch with Better Seal, Shock
Resistance, and Strength
• A double seal on the head, a complete gasket cover, and other
• Wide standard operating temperature range:
• Models with fluoro-rubber available for greater resistance to
• Block mounting method also reduces downtime for maintenance.
• DPDT, double-break models available for complex operations.
• Approved by UL, CSA, and CCC (Chinese standard).
Model Number Structure
Model Number Legend
D4A-@@@@N (Set model number)
(1) Receptacle box
(2) Switch Box
*1. Use the D4A-0017N Special Head.
*2. Use the D4A-0018N Special Head.
Note: Fluoro-rubber sealed type is also available.
E : SPDT, double-break, LED (24 VDC, leakage current: 1.3 mA)
P : DPDT, double-break, simultaneous operation, LED
1 : 1/2-14 NPT conduit (SPDT, double-break)
2 : 1/2-14 NPT conduit (DPDT, double-break)
3 : G 1/2 conduit (SPDT, double-break)
4 : G 1/2 conduit (DPDT, double-break)
1 : SPDT, double-break, without indicator
3 : SPDT, double-break, neon lamp
5 : DPDT, double-break, simultaneous operation, without indicator
7 : DPDT, double-break, sequential operation, without indicator *1
9 : DPDT, double-break, center neutral operation, without indicator *2
L : DPDT, double-break, simultaneous operation, neon lamp
features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
−40°C to +100°C (standard type).
chemicals.
(Ask your OMRON representative for information on approved model.)
General-purpose Limit Switch
D4A-@N
Be sure to read Safety Precautions on page 14 to 15 and
Safety Precautions for All Limit Switches.
(1) (2) (3)
(Not all combinations are possible. Ask your OMRON representative for details.)
(3) Head
07-V : Side plunger, vertical roller
07-H : Side plunger, horizontal roller
01
02
03
04
05
17
18
06
08
09
10
11
12
14
15
16
: Roller lever, standard
: Roller lever, high-sensitivity
: Roller lever, low torque
: Roller lever, high-sensitivity, low torque
: Roller lever, maintained
: Roller lever, sequential operation
: Roller lever, center neutral operation
: Side plunger, standard
: Side plunger, adjustable
: Top plunger, standard
: Top plunger, roller
: Top plunger, adjustable
: Flexible rod, spring wire
: Flexible rod, plastic rod
: Flexible rod, cat whisker
: Flexible rod, coil spring
CSM_D4A-_N_DS_E_2_1
1

Related parts for D4A-E00

D4A-E00 Summary of contents

Page 1

... DPDT, double-break, sequential operation, without indicator * DPDT, double-break, center neutral operation, without indicator * DPDT, double-break, simultaneous operation, neon lamp P : DPDT, double-break, simultaneous operation, LED *1. Use the D4A-0017N Special Head. *2. Use the D4A-0018N Special Head. Note: Fluoro-rubber sealed type is also available. CSM_D4A-_N_DS_E_2_1 (3) Head 01 ...

Page 2

... Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is −10 to +120°C.) Add “-F” to the model number. (Example: D4A-3101N becomes D4A-3101N-F.) Ask your nearest OMRON representative for details. *1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer to Levers on page 12). ...

Page 3

... Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is −10 to +120°C.) Add “-F” to the model number. (Example: D4A-4501N becomes D4A-4501N-F.) Ask your nearest OMRON representative about delivery times and prices. ...

Page 4

... Levers for Roller Lever Switches are optionally available. Select the lever from those listed in this data sheet and order (refer to Levers on page 12). *2. The D4A-C00 adjustable roller lever is too heavy and long for these heads and it should not be used or mechanical malfunction will result. ...

Page 5

... Motor loads have an inrush current of 6 times the steady-state current. Model D4A-A00 D4A-A10 D4A-A20 D4A-A30 D4A-B06 D4A-C00 D4A-D00 D4A-F00 D4A-E30 D4A-E20 D4A-E10 D4A-E00 File No. E76675 LR45746 2003010305077615 Ratings for Models with Indicators and Indicator Replacement Inductive load (A) Inductive Ratings for Indicators Motor load load Classi- ...

Page 6

... SPDT, double-break: for 125 VAC resistive load: 1,000,000 opera- tions min. DPDT, double-break: for 125 VAC resistive load: 750,000 operations min m/s (in case of D4A-3101N roller lever model) 300 operations/minute 30 operations/minute 50/60 Hz 100 MΩ min. (at 500 VDC) between ...

Page 7

... D4A-@ Easy-maintenance Block Mounting Block mounting makes it possible to easily assemble or disassemble the head, switch body, and @ receptacle of the D4A tightening or loosening the attached screws. Head Actuator Switch box Receptacle 7 ...

Page 8

... Remarks Energized Head is compatible with double-break head. Can be switched for operation on both sides of actuator. Stroke Energized Use the D4A-0017N Spe- cial Head. Stroke Energized Use the D4A-0018N Spe- cial Head. Left Free Right operation position operation With LED indicator * D4A-0P00N Lamp ...

Page 9

... High-sensitivity D4A-3@02N, D4A-4@02N Low-torque D4A-3@03N, D4A-4@03N High-sensitivity/Low-torque D4A-3@04N, D4A-4@04N Sequential Operation D4A-4@17N Center Neutral Operating D4A-4@18N Maintained D4A-3 05N, D4A-4 05N @ @ Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Model SPDT Double-break D4A- D4A- Operating characteristics 3@01N 3@02N Operating force OF max. ...

Page 10

... MD max. 0.4 mm 75.5 46±0 Operating position Two, M6 (depth: 10) screws 16.5 for back-mounting 28 G1/2 29.5 conduit 44 Note: A Fork Lever Lock can be used with D4A-@@05N models only. D4A-@N Four, M4 (length: 12) screws for head 21.5 31.1 19 +0.2 5.2 dia. 0 mounting holes R2.6 59.5±0.2 70 ...

Page 11

... Two, M6 (depth: 10) screws 16.5 for back-mounting 28 29.5 G1/2 44 conduit SPDT Double-break D4A-3@15N D4A-3@16N D4A-4@12N 1.47 N 15° (5°) 15° (5°) D4A-@N (see note 1) 7 dia. PT Plastic rod (see note 2) 21 Four, M4 (length: 12) screws for head 150 88.5 27 +0.2 5 ...

Page 12

... Stainless 3.6 sintered roller ° dia. 38.1 7.3 dia. Stainless M5 Allen bolt sintered 9 38.1 roller Fork Lever Lock D4A-E00 Note: A Fork Lever Lock can be used with 26 D4A-@@05N 22 models only. (2) 6.2 7.9 Stainless 3.6 sintered roller ° dia. 38.1 7 ...

Page 13

... Four There are four kinds of fork lever locks. The position of each roller is different possible to use D4A-E00 through D4A-E30 levers instead, if they are reversed before attaching. They can be used with D4A- @@ 05N models only. ...

Page 14

... Remove the lamp 3. Mount the lamp section section. so that legend “NC-ON” or “NO-ON” will appear in the display window. G1/2 Conduit Mounting lo- D4A-3@@@N cations D4A-4@@@N +0.2 Two, 5.2 dia. holes tapped holes 59.5 ± 0.15 : Mounting locations 29.4 ± 0.15 +0.2 Two, 6 ...

Page 15

... Tighten the Connectors to a torque of 1.8 to 2.2 N·m. Maintenance and Repair The user must not maintain or repair equipment incorporating any D4A-N model. Contact the manufacturer of the equipment for any maintenance or repairs required. How to Order The D4A-@N is compatible with the D4A-@ when the following accessories are attached to the D4A-@N ...

Page 16

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords