D4BS-2BFS Omron, D4BS-2BFS Datasheet
D4BS-2BFS
Specifications of D4BS-2BFS
Related parts for D4BS-2BFS
D4BS-2BFS Summary of contents
Page 1
... G1/2 1/2–14NPT M20 CSM_D4BS_DS_E_3_1 Note: Contact your sales representative for details on models with safety standard certification. Operation Key D4BS - Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) Note: An order for the head part or the switch part alone cannot be accepted. (The Operation Key is sold separately ...
Page 2
... Model D4BS-K1 D4BS-K2 D4BS-K3 Certified Standards Certification body TÜV Rheinland UL CSA CQC (CCC) AC-15 Current (A) Make Break 1.5 12 1.2 D4BS Standard File No. EN60947-5-1 (certified direct J50084815 opening) GS-ET-15 UL508 E76675 CSA C22.2 No. 14 LR45746 GB14048.5 2003010305073833 Volt-amperes (VA) Make Break 7,200 720 2 ...
Page 3
... The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. ...
Page 4
... Structure and Nomenclature Structure Operation Key D4BS's exclusive-use Operation Key is provided to assure accurate switching operation. Set Zone Mark A triangular Set Zone Mark makes it easy to adjust the operating position when inserting the Operation Key. Built-in Switch A shearing force contact separating mechanism (NC contact) is employed, which positively pulls apart the ...
Page 5
... Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. There are fluctuations in the contact ON/OFF timing for 2NC contacts. Confirm performance before application. * The conduit thread varies with the model as follows: D4BS-1@@S, D4BS-5@@S: Pg 13.5 D4BS-2@@S, D4BS-6@@S: G1/2 D4BS-3@@S, D4BS-7@@S: 1/2-14NPT 31 ...
Page 6
... D4BS-1@@S + D4BS-K2 D4BS-2@@S + D4BS-K2 D4BS-3@@S + D4BS-K2 Red Operation Key insertion radius in horizontal direction: R ≥ 1200 54.5 min. 59 max. (40 ) ±0.15 (41) (13) Operation Key insertion radius in vertical direction: R ≥ 1000 54.5 min. ...
Page 7
... Head mounting screw M5 body mounting screw *2 Operation Key mounting screw Connector Cap screw *1. Apply a torque of 0.78 to 0.88 N·m if the D4BS is a three-conduit model. *2. Apply a torque of 4.90 to 5.88 N·m for an Allen-head bolt. For a Incorrect pan head screw, apply a torque of 2.35 to 2.75 N·m. ...
Page 8
... Operation Key Make sure that the Operation Key can be inserted properly with a tolerance of ±0 the upward, downward, left, or right direction. Otherwise the D4BS may soon become damaged due to misalignment. Observe the specified insertion radius for the Operation Key and insert direction perpendicular to the key hole. Do not use the D4BL operation key ...
Page 9
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...