D4GS-N1R-5 Omron, D4GS-N1R-5 Datasheet

no-image

D4GS-N1R-5

Manufacturer Part Number
D4GS-N1R-5
Description
SLIM SAFETY LS,1NC/1NO,HORZ,5M
Manufacturer
Omron
Series
D4GS-Nr
Datasheet

Specifications of D4GS-N1R-5

Lead Free Status / Rohs Status
 Details
Slim Safety Door Switches with IP67 Rating
Model Number Structure
Model Number Legend
Ordering Information
List of Models
Switches (Operation Keys are sold separately.)
Consult with your OMRON representative when ordering any models that are not listed in this table.
Operation Keys
Switch
D4GS-N@@-@
Horizontal mounting
Vertical mounting
• Slim design with a width of only 17 mm
• Reversible design allowing either front or rear mounting.
• Built-in Switches with two- or three-terminal contact
• Operation Key with rubber mounting hole to absorb vibration and
• IP67 degree of protection.
1. Built-in Switch
Slim Safety Door Switch
D4GS-N
(three-contact models).
construction are available.
shock.
Appearance
1: 1NC/1NO (slow-action)
2: 2NC (slow-action)
3: 2NC/1NO (slow-action)
4: 3NC (slow-action)
Be sure to read the “Safety Precautions” on page 8 and the
“Precautions for All Safety Door Switches”.
Type
1 2 3
Operation Key
Direction of
Horizontal
insertion
Vertical
D4GS-NK1
D4GS-NK2
Model
2. Direction of Operation
Key Insertion
R: Horizontal
T:
Cable length
Vertical
1 m
3 m
5 m
1 m
3 m
5 m
Adjustable mounting
(Vertical)
D4GS-N1R
D4GS-N1R-3
D4GS-N1R-5
D4GS-N1T
D4GS-N1T-3
D4GS-N1T-5
Type
(Slow-action)
1NC/1NO
3. Cable Length
Blank: 1 m
3:
5:
D4GS-N2R
D4GS-N2R-3
D4GS-N2R-5
D4GS-N2T
D4GS-N2T-3
D4GS-N2T-5
.
3 m
5 m
(Slow-action)
D4GS-NK4
Model
2NC
: Models with certified direct opening contacts.
1. Operation Key Type
Operation Key
D4GS-NK@
1: Horizontal mounting
2: Vertical mounting
4: Adjustable mounting (Vertical)
D4GS-N3R
D4GS-N3R-3
D4GS-N3R-5
D4GS-N3T
D4GS-N3T-3
D4GS-N3T-5
(Slow-action)
2NC/1NO
1
CSM_D4GS-N_DS_E_5_1
D4GS-N4R
D4GS-N4R-3
D4GS-N4R-5
D4GS-N4T
D4GS-N4T-3
D4GS-N4T-5
(Slow-action)
3NC
1

Related parts for D4GS-N1R-5

D4GS-N1R-5 Summary of contents

Page 1

... Vertical mounting D4GS-NK2 . 3. Cable Length Blank Vertical 1NC/1NO Cable length (Slow-action) (Slow-action D4GS-N1R D4GS-N2R 3 m D4GS-N1R-3 D4GS-N2R D4GS-N1R-5 D4GS-N2R D4GS-N1T D4GS-N2T 3 m D4GS-N1T-3 D4GS-N2T D4GS-N1T-5 D4GS-N2T-5 Type Model Adjustable mounting (Vertical) D4GS-NK4 CSM_D4GS-N_DS_E_5_1 Operation Key D4GS-NK Operation Key Type 1: Horizontal mounting ...

Page 2

... Certification for CSA C22.2 No authorized by the UL mark. DC-13 0.27 A 250 V Current (A) Make Break 15 1.5 7.5 0.75 Current (A) Make Break 0.55 0.55 0.27 0.27 D4GS-N Standard File No. EN60947-5-1 Consult your OMRON representative for opening) details. GS-ET-15 UL508 E76675 GB14048.5 2003010305064262 Volt-amperes (VA) Make Break 1,800 180 ...

Page 3

... Although the switch box is protected from dust, oil, or water penetration, do not use the D4GS-N in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. ...

Page 4

... Stroke 22 Extraction Operation Key insertion completion 32 position completion position D4GS-N Mounting Reversible design allowing either front or rear mounting. IP67 degree of protection Remarks Only NC contact 11-12 has a ON certified direct opening mechanism. The terminals 11-12 and 33-34 can be used as unlike poles. ...

Page 5

... Operating characteristics UL Style 2464 Key insertion force AWG22 Key extraction force Finishing O.D.: 7.2 mm dia. Pretravel (PT) Movement before being locked Direct opening force Direct opening stroke UL Style 2464 AWG22 Finishing O.D.: 7.2 mm dia. D4GS-N (Unit: mm max max. 6.8±3 mm (22 mm min min. 5 ...

Page 6

... R ≤ 240. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Dimensions in parentheses are reference values. D4GS-NK2 Red Two, 9 dia. Mounting Two, 9 dia. rubber Two, 4.3 dia. D4GS-N@T-@ + D4GS-NK1 Key insertion radius (R ≥ 170) Red Black Key insertion Key insertion face radius (12.3± ...

Page 7

... Use the D4GS-NK1 or D4GS-NK2 hole of the Switch. if necessary. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Dimensions in parentheses are reference values. D4GS-N@T-@ + D4GS-NK2 ...

Page 8

... Conduit Bending radius more than Fixing unit • Do not fasten or loosen the conduit at the bottom of the D4GS-N. • When wiring, be sure not to allow a liquid such as water or oil into the tip of cable. Stopper Installation Do not use a Switch as a stopper. Be sure to install a stopper as shown in the following illustration when mounting the Switch and adjust the stopper so that the Operation Key is within the setting zone ...

Page 9

... M4 screw • Identify terminal numbers based on the color of the insulation on the wire. M4 screw • The safety and auxiliary contacts of D4GS-N models of three-terminal contact construction and those of two-terminal contact construction are described below. The following shows contact form with key inserted. • The auxiliary contacts (orange) can be used as safety contacts. ...

Page 10

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords