E2A3-M30KS20-M1-B1 Omron, E2A3-M30KS20-M1-B1 Datasheet
E2A3-M30KS20-M1-B1
Specifications of E2A3-M30KS20-M1-B1
Related parts for E2A3-M30KS20-M1-B1
E2A3-M30KS20-M1-B1 Summary of contents
Page 1
... E2A3-M12KS06-M1-C1 PNP E2A3-M18KS11-WP-B1 2M E2A3-M18KS11-WP- (60) mm NPN E2A3-M18KS11-WP-C1 2M E2A3-M18KS11-WP-C2 2M Brass PNP E2A3-M18KS11-M1-B1 39 (54) mm NPN E2A3-M18KS11-M1-C1 PNP E2A3-M30KS20-WP-B1 2M E2A3-M30KS20-WP- (65) mm NPN E2A3-M30KS20-WP-C1 2M E2A3-M30KS20-WP-C2 2M Brass PNP E2A3-M30KS20-M1-B1 44 (59) mm NPN E2A3-M30KS20-M1-C1 Operation mode: NO Operation mode: NC E2A3-S08KS03-M1-B2 E2A3-S08KS03-M1-C2 E2A3-S08KS03-M5-B2 E2A3-S08KS03-M5-C2 E2A3-M12KS06-M1-B2 E2A3-M12KS06-M1-C2 E2A3-M18KS11-M1-B2 E2A3-M18KS11-M1-C2 E2A3-M30KS20-M1-B2 E2A3-M30KS20-M1-C2 1 ...
Page 2
... Connectivity E2A3 Sensors are available with the following connectors and cable materials: Pre-wired Models Standard cable lengths are 2 m and 5 m. For other cable lengths, please contact your OMRON representative. Standard cable material: PVC (4-mm dia.) Model Number Legend E2A@-@@@@@-@-@@-@@ Example: E2A3-M12KS06-M1-B1 E2A3-S08KS03-WP- ...
Page 3
... Output reverse polarity protection, Power source circuit reverse polarity protec- tion, Surge suppressor, Short-circuit protection times each 2 1,000 m times each and Z directions Approx Approx Brass-nickel plated Brass-nickel plated M18 M30 Shielded Shielded E2A3-M18KS11-@@-B@ E2A3-M30KS20-@@-B@ E2A3-M30KS20-@@-C@ E2A3-M18KS11-@@- ± 10 ± × 33 × × 60 × 250 Approx. 160 g Approx. 280 g Approx Approx ...
Page 4
... Aluminum 1.0 Copper 0.5 0 Side length of sensing object d (mm) E2A3-M30KS20 Iron 20 Stainless steel (SUS303) 15 Brass 10 Aluminum Copper Side length of sensing object d (mm E2A3-M12KS06 Iron Stainless steel (SUS303) 4 Brass Aluminum 3 Copper Side length of sensing object d (mm) 60 E2A3-M18KS11 Iron 10 Stainless steel (SUS303 Brass ...
Page 5
... Operation DC 3-wire Models PNP Output Operation mode Model NO E2A3-@-@-B1 NC E2A3-@-@-B2 E2A3 Cylindrical Proximity Sensor Timing chart Non-sensing area Sensing area Sensing object (%) 100 0 ON Yellow indicator OFF ON Control output OFF Non-sensing area Sensing area Sensing object 100 0 (%) ON Yellow indicator ...
Page 6
... Black Sensor main (M8 connector: circuits Blue Note 1: With M8 Size Models, there is no output reverse polarity protection diode. M8 Connector M12 Connector Pin Arrangement (3-pin) (See note 2.) Pin Arrangement Note 2: Terminal 4 of the M12 connector is not used. E2A3 Cylindrical Proximity Sensor + ...
Page 7
... Indicator (See note 2.) M18×1 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conduc- 2 tor cross section: 0 Insulator diameter: 1.3 mm), Standard length Operation indicator (yellow) E2A3-M30KS20-WP-@@ 64 Indicator (See note 2.) M30×1.5 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conduc- 2 tor cross section: 0 ...
Page 8
... Indicator (See note.) M8×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4 × 90 ° ) Mounting Hole Cutout Dimensions External diameter of Proximity Sensor M8 M12 F M18 M30 8 Dimension F (mm) +0.5 8.5 dia. 0 +0.5 12.5 dia. 0 +0.5 18.5 dia. 0 +0.5 30.5 dia. 0 E2A3 Cylindrical Proximity Sensor ...
Page 9
... E2A3 d 54 Shielded Using the nuts provided with the E2A3 allows mounting in the way shown be- low. Nut provided with E2A3 E2A3 Cylindrical Proximity Sensor Wiring Be sure to wire the E2A3 and load correctly, otherwise it may be damaged. Connection with No Load Be sure to insert a load when wiring. Make sure to connect a proper load to the E2A3 during operation, otherwise it may damage internal elements ...
Page 10
... Operating Environment Store and operate the Proximity Sensor only within the given specifi- cations. Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor. Connect the load to the Proximity Sensor through a relay. Cylindrical Proximity Sensor E2A3 ...
Page 11
... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...
Page 12
Cat. No. D102-E1-01 Specifications subject to change without notice 5/06 Printed in USA ...