E2AS08LN04M1C1 Omron, E2AS08LN04M1C1 Datasheet

M8,LNG,UNSH,SS,4mm,NPN,NO,M12

E2AS08LN04M1C1

Manufacturer Part Number
E2AS08LN04M1C1
Description
M8,LNG,UNSH,SS,4mm,NPN,NO,M12
Manufacturer
Omron
Datasheet

Specifications of E2AS08LN04M1C1

Output Type
NPN
Proximity Sensor Sensing Distance
4mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Mounting
Panel
Operating Temp Range
-40C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
32V
Pin Count
4
Lead Free Status / Rohs Status
Compliant
Safe Mounting with Greater
Sensing Distance
• Ensures a sensing distance approximately 1.5 to 2
• Problems such as the collision of workpieces are
• Full range of standard sizes (M8, M12, M18 and
• Modular construction simplifies customization.
<READ AND UNDERSTAND THIS CATALOG>
Please read and understand this catalog before purchasing
the products. Please consult your OMRON representative if
you have any questions or comments.
Ordering Information
M8
times larger than that of any conventional OMRON
Sensor.
eliminated.
M30; both long and short barrels)
Cylindrical Proximity Sensor
E2A
Shielded
Non-shielded
Size
2.0 mm
4.0 mm
distance
Sensing
Pre-wired
M12 connector
M8 connector (3-
pin)
Pre-wired
M12 connector
M8 connector (3-
pin)
Connection
Stainless
steel
Stainless
steel
Brass
Stainless
steel
Stainless
steel
Stainless
steel
Brass
Stainless
steel
material
Body
27 (40)
49 (62)
27 (43)
49 (65)
27 (43)
49 (65)
27 (39)
49 (61)
27 (40)
49 (62)
27 (43)
49 (65)
27 (43)
49 (65)
27 (39)
49 (61)
(overall length)
Thread length
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
configuration
Output
E2A
E2A-S08KS02-WP-B1 2M
E2A-S08KS02-WP-C1 2M
E2A-S08LS02-WP-B1 2M
E2A-S08LS02-WP-C1 2M
E2A-S08KS02-M1-B1
E2A-S08KS02-M1-C1
E2A-S08LS02-M1-B1
E2A-S08LS02-M1-C1
E2A-M08KS02-M1-B1
E2A-M08KS02-M1-C1
E2A-M08LS02-M1-B1
E2A-M08LS02-M1-C1
E2A-S08KS02-M5-B1
E2A-S08KS02-M5-C1
E2A-S08LS02-M5-B1
E2A-S08LS02-M5-C1
E2A-S08KN04-WP-B1 2M
E2A-S08KN04-WP-C1 2M
E2A-S08LN04-WP-B1 2M
E2A-S08LN04-WP-C1 2M
E2A-S08KN04-M1-B1
E2A-S08KN04-M1-C1
E2A-S08LN04-M1-B1
E2A-S08LN04-M1-C1
E2A-M08KN04-M1-B1
E2A-M08KN04-M1-C1
E2A-M08LN04-M1-B1
E2A-M08LN04-M1-C1
E2A-S08KN04-M5-B1
E2A-S08KN04-M5-C1
E2A-S08LN04-M5-B1
E2A-S08LN04-M5-C1
Cylindrical Proximity Sensor
Operation mode NO
E2A-S08KS02-WP-B2 2M
E2A-S08KS02-WP-C2 2M
E2A-S08LS02-WP-B2 2M
E2A-S08LS02-WP-C2 2M
E2A-S08KS02-M1-B2
E2A-S08KS02-M1-C2
E2A-S08LS02-M1-B2
E2A-S08LS02-M1-C2
E2A-M08KS02-M1-B2
E2A-M08KS02-M1-C2
E2A-M08LS02-M1-B2
E2A-M08LS02-M1-C2
E2A-S08KS02-M5-B2
E2A-S08KS02-M5-C2
E2A-S08LS02-M5-B2
E2A-S08LS02-M5-C2
E2A-S08KN04-WP-B2 2M
E2A-S08KN04-WP-C2 2M
E2A-S08LN04-WP-B2 2M
E2A-S08LN04-WP-C2 2M
E2A-S08KN04-M1-B2
E2A-S08KN04-M1-C2
E2A-S08LN04-M1-B2
E2A-S08LN04-M1-C2
E2A-M08KN04-M1-B2
E2A-M08KN04-M1-C2
E2A-M08LN04-M1-B2
E2A-M08LN04-M1-C2
E2A-S08KN04-M5-B2
E2A-S08KN04-M5-C2
E2A-S08LN04-M5-B2
E2A-S08LN04-M5-C2
Operation mode NC
1

Related parts for E2AS08LN04M1C1

E2AS08LN04M1C1 Summary of contents

Page 1

... Full range of standard sizes (M8, M12, M18 and M30; both long and short barrels) • Modular construction simplifies customization. <READ AND UNDERSTAND THIS CATALOG> Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Ordering Information Size Sensing ...

Page 2

Size Sensing Connection distance M12 Shielded 4.0 mm Pre-wired M12 connector Non-shielded 8.0 mm Pre-wired M12 connector M18 Shielded 8.0 mm Pre-wired M12 connector Non-shielded 16.0 mm Pre-wired M12 connector M30 Shielded 15.0 mm Pre-wired M12 connector Non-shielded 20.0 mm ...

Page 3

Model Number Legend E2A@-@@@@@-@-@@-@@ Example: E2A-M12LS04-M1-B1 E2A-M08KN04-WP- Basic name E2A 2. Sensing technology Blank: Standard double distance 3. Housing shape and material M: Cylindrical, metric ...

Page 4

Specifications ■ DC 3-wire Models Size Type Item Sensing distance Setting distance Differential travel Target Standard target (mild steel ST37) Response frequency (See note 1.) Power supply voltage (operating voltage range) Current consumption (DC 3-wire) Output type Control Load current ...

Page 5

DC 3-wire Models Size Type Shielded E2A-M18@S08-@@-B1 E2A-M18@S08-@@-B2 E2A-M18@S08-@@-C1 Item E2A-M18@S08-@@-C2 Sensing distance 8 mm±10% Setting distance 0 to 6.4 mm Differential travel 10% max. of sensing distance Target Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard ...

Page 6

Engineering Data Operating Range (Typical) Shielded Models 18 E2A-M30@S15 E2A-M18@S08 10 8 E2A-M12@S04 6 E2A-S08@S02/ E2A-M08@S02 −30 −20 − Distance Y (mm) Influence of Sensing Object Size and Materials ...

Page 7

Non-shielded Models E2A-S08@N04/M08@N04 5 Iron 4.0 Stainless steel (SUS303) 3.0 Brass 2.0 Aluminum Copper 1 Side length of sensing object d (mm) E2A-M30KN20 ...

Page 8

Operation ■ PNP Output Operation mode Model NO E2A-@-@-B1 NC E2A-@-@-B2 E2A 8 Cylindrical Proximity Sensor Timing chart Non-sensing zone Sensing zone Sensing object 100 0 (%) ON Yellow indicator OFF ON Control output OFF Non-sensing zone Sensing zone Sensing ...

Page 9

NPN Output Operation mode Model NO E2A-@-@-C1 NC E2A-@-@-C2 Timing chart Non-sensing zone Sensing zone Sensing object 100 0 (%) ON Yellow indicator OFF ON Control output OFF Non-sensing zone Sensing zone Sensing object 100 0 (%) ON Yellow ...

Page 10

Dimensions Note: All units are in millimeters unless otherwise indicated. Pre-wired Models (Shielded) E2A-S08KS02-WP-@@ (See note 1.) Indicator (See note 2.) M8×1 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor ...

Page 11

E2A-S08LS02-WP-@@ (See note 1.) Indicator (See note 2.) M8×1 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0 insulator diameter: 1.3 mm); standard length: 2 ...

Page 12

M12 Connector Models (Shielded) E2A-S08KS02-M1-@@ E2A-M08KS02-M1-@@ Indicator (See note.) M8×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) E2A-M12KS04-M1-@@ M12×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) ...

Page 13

E2A-S08LS02-M1-@@ E2A-M08LS02-M1-@@ M8×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) E2A-M12LS04-M1-@@ M12×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) E2A-M18LS08-M1-@@ M18×1 Two, clamping nuts Note: ...

Page 14

Precautions ■ Safety Precautions Power Supply Do not impose an excessive voltage on the E2A, otherwise it may be damaged. Do not impose AC current (100 to 240 VAC) on any DC model, otherwise it may be damaged. Load Short-circuit ...

Page 15

Wiring High-tension Lines Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to pre- vent against Proximity Sensor damage or malfunctioning. Cable ...

Page 16

... PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’ ...

Page 17

... Cat. No. D100-E1-01B OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Rights Reserved. 2008.7 ...

Related keywords