E2AS08LN04M1C1 Omron, E2AS08LN04M1C1 Datasheet
E2AS08LN04M1C1
Specifications of E2AS08LN04M1C1
Related parts for E2AS08LN04M1C1
E2AS08LN04M1C1 Summary of contents
Page 1
... Full range of standard sizes (M8, M12, M18 and M30; both long and short barrels) • Modular construction simplifies customization. <READ AND UNDERSTAND THIS CATALOG> Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Ordering Information Size Sensing ...
Page 2
Size Sensing Connection distance M12 Shielded 4.0 mm Pre-wired M12 connector Non-shielded 8.0 mm Pre-wired M12 connector M18 Shielded 8.0 mm Pre-wired M12 connector Non-shielded 16.0 mm Pre-wired M12 connector M30 Shielded 15.0 mm Pre-wired M12 connector Non-shielded 20.0 mm ...
Page 3
Model Number Legend E2A@-@@@@@-@-@@-@@ Example: E2A-M12LS04-M1-B1 E2A-M08KN04-WP- Basic name E2A 2. Sensing technology Blank: Standard double distance 3. Housing shape and material M: Cylindrical, metric ...
Page 4
Specifications ■ DC 3-wire Models Size Type Item Sensing distance Setting distance Differential travel Target Standard target (mild steel ST37) Response frequency (See note 1.) Power supply voltage (operating voltage range) Current consumption (DC 3-wire) Output type Control Load current ...
Page 5
DC 3-wire Models Size Type Shielded E2A-M18@S08-@@-B1 E2A-M18@S08-@@-B2 E2A-M18@S08-@@-C1 Item E2A-M18@S08-@@-C2 Sensing distance 8 mm±10% Setting distance 0 to 6.4 mm Differential travel 10% max. of sensing distance Target Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard ...
Page 6
Engineering Data Operating Range (Typical) Shielded Models 18 E2A-M30@S15 E2A-M18@S08 10 8 E2A-M12@S04 6 E2A-S08@S02/ E2A-M08@S02 −30 −20 − Distance Y (mm) Influence of Sensing Object Size and Materials ...
Page 7
Non-shielded Models E2A-S08@N04/M08@N04 5 Iron 4.0 Stainless steel (SUS303) 3.0 Brass 2.0 Aluminum Copper 1 Side length of sensing object d (mm) E2A-M30KN20 ...
Page 8
Operation ■ PNP Output Operation mode Model NO E2A-@-@-B1 NC E2A-@-@-B2 E2A 8 Cylindrical Proximity Sensor Timing chart Non-sensing zone Sensing zone Sensing object 100 0 (%) ON Yellow indicator OFF ON Control output OFF Non-sensing zone Sensing zone Sensing ...
Page 9
NPN Output Operation mode Model NO E2A-@-@-C1 NC E2A-@-@-C2 Timing chart Non-sensing zone Sensing zone Sensing object 100 0 (%) ON Yellow indicator OFF ON Control output OFF Non-sensing zone Sensing zone Sensing object 100 0 (%) ON Yellow ...
Page 10
Dimensions Note: All units are in millimeters unless otherwise indicated. Pre-wired Models (Shielded) E2A-S08KS02-WP-@@ (See note 1.) Indicator (See note 2.) M8×1 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor ...
Page 11
E2A-S08LS02-WP-@@ (See note 1.) Indicator (See note 2.) M8×1 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0 insulator diameter: 1.3 mm); standard length: 2 ...
Page 12
M12 Connector Models (Shielded) E2A-S08KS02-M1-@@ E2A-M08KS02-M1-@@ Indicator (See note.) M8×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) E2A-M12KS04-M1-@@ M12×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) ...
Page 13
E2A-S08LS02-M1-@@ E2A-M08LS02-M1-@@ M8×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) E2A-M12LS04-M1-@@ M12×1 Two, clamping nuts Note: Operation indicator (yellow LED, 4×90°) E2A-M18LS08-M1-@@ M18×1 Two, clamping nuts Note: ...
Page 14
Precautions ■ Safety Precautions Power Supply Do not impose an excessive voltage on the E2A, otherwise it may be damaged. Do not impose AC current (100 to 240 VAC) on any DC model, otherwise it may be damaged. Load Short-circuit ...
Page 15
Wiring High-tension Lines Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to pre- vent against Proximity Sensor damage or malfunctioning. Cable ...
Page 16
... PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’ ...
Page 17
... Cat. No. D100-E1-01B OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Rights Reserved. 2008.7 ...