E2CA-X2A Omron, E2CA-X2A Datasheet

ANALOG PROX M12, .4-2.0mm, 3M

E2CA-X2A

Manufacturer Part Number
E2CA-X2A
Description
ANALOG PROX M12, .4-2.0mm, 3M
Manufacturer
Omron
Type
Inductive Proximity Sensorr
Series
E2CAr
Datasheets

Specifications of E2CA-X2A

Proximity Sensor Type
Inductive
Proximity Sensor Sensing Distance
2mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO/NC
Mounting
Panel
Operating Temp Range
-25C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
30V
Pin Count
2
Maximum Operating Temperature
+ 70 C
Sensing Distance
2 mm
Minimum Operating Temperature
- 25 C
Features
NO / NC
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
10kHz
Material - Body
Nickel-Plated Brass
Shielding
Shielded
Voltage - Supply
-
Output Type
-
Terminal Type
2-Wire
Package / Case
Cylinder, Threaded - M12
Lead Free Status / Rohs Status
Supplier Unconfirmed
E2CA
Threaded Cylindrical Inductive Sensor with
Separate Amplifier Provides Precision
Linear Analog Output and a Discrimination
Output
Ordering Information
Part
number
Required sensor
Part
number
Outputs
Description
Mounting brackets for sensors
Sockets for amplifiers
Sensor type
Size
Nominal sensing
distance
Special-Purpose Proximity Sensor
Linear 4 to 20 mA output for target to sensor
distance
Position measurements accurate to
Adjustable setpoint controls switching output
rated 100 mA is NO/NC selectable
Amplifier has power ON, target detected,
and discrimination output indicators
AC amplifier has universal voltage rating
90 to 264 VAC
DC amplifier rated 10 to 30 VDC
Sensors available in standard 8, 12, 18,
30 mm sizes with sensing distances
up to 10 mm
SENSOR
AMPLIFIER
ACCESSORIES
0.0006 mm with 0.05% full scale resolution
AC power supply
DC power supply
3 m (9.8 ft) cable
5 m (16.4 ft) cable
Fits M8 size sensors
Fits M12 size sensors
Fits M18 size sensors
Fits M30 size sensors
Combination bottom surface and track mounting socket with
screw terminals
Back mounting socket with screw terminals for panel mount applications P3GA-11
Circuit board socket with solder terminals
Shielded
E2CA-X1R5A
E2CA-X1R5A-5M
M8
0.3 to 1.5 mm
(0.01 to 0.06 in)
E2CA-X1R5A/-5M
E2CA-AN4C
E2CA-AL4C
Linear output, 4 to 20 mA; Switching output, selectable NO or NC transistor
(This table continues on the following page.)
E2CA-X2A/-5M
E2CA-AN4D
E2CA-AL4D
E2CA-X2A
E2CA-X2A-5M
M12
0.4 to 2.0 mm
(0.02 to 0.08 in)
1.5, 2, 5, 10 mm
Sensing
Supply voltage
90 to 264 VAC,
50/60 Hz
amplifier or
10 to 30 VDC
amplifier
E2CA-X5A/-5M
E2CA-AN4E
E2CA-AL4E
E2CA-X5A
E2CA-X5A-5M
M18
1 to 5 mm
(0.04 to 0.20 in)
4 to 20 mA
E2CA-X10A
E2CA-X10A-5M
M30
2 to 10 mm
(0.08 to 0.39 in)
E2CA-X10A/-5M
E2CA-AN4F
E2CA-AL4F
Part number
Y92E-B8
Y92E-B12
Y92E-B18
Y92E-B30
P2CF-11
PL-11
Output
E2CA
100 mA, 40 VDC
E2CA
69

Related parts for E2CA-X2A

E2CA-X2A Summary of contents

Page 1

... VAC, 50/60 Hz amplifier VDC amplifier 1. E2CA-X2A E2CA-X5A E2CA-X2A-5M E2CA-X5A-5M M12 M18 0 (0.02 to 0.08 in) (0.04 to 0.20 in) E2CA-X2A/-5M E2CA-X5A/-5M E2CA-AN4D E2CA-AN4E E2CA-AL4D E2CA-AL4E (This table continues on the following page.) E2CA E2CA Output 100 mA, 40 VDC E2CA-X10A E2CA-X10A-5M M30 (0.08 to 0.39 in) ...

Page 2

... IEC 144 IP67 Approvals UL — CSA — Ambient operating - (-13 to 158 F) temperature Vibration Hz, 1.5 mm (0.06 in) double amplitude Shock Approx E2CA-X2A/-5M E2CA-X5A/-5M M12 M18 E2CA-AL4D or E2CA-AL4E or E2CA-AN4D E2CA-AN4E 2 mm (0.08 in (0.20 in) 0 (0.02 to 0.08 in) (0.04 to 0.20 in (0.47 x 0.47 x 0.04 in) (0 ...

Page 3

... NEMA 1 IEC 144 IP40 Approvals UL — CSA — Ambient operating temperature – (–14 to 131 F) Vibration Hz (0.08 in) double amplitude Shock Approx E2CA-A 4D E2CA-A 4E E2CA-X2A E2CA-X5A 2.0% of full scale 1.5% of full scale 5 kHz 1.5 kHz E2CA E2CA-A 4F E2CA-X10A 2.0% of full scale 3 kHz 1 kHz 71 ...

Page 4

... SPAN indicator (Green LED) Indicates the linear area of the output current OPER. indicator (Red LED) Illuminates when the target is present within the range from the minimum sensing distance to the target setpoint distance Linear output current adjustment (20 mA) Linear output current adjustment (4 mA) E2CA ...

Page 5

... OPER. indicator illuminates when the object to be detected is at the specified position and that the indicator goes OFF when the target is moved away from that position. If the target moves in parallel with the surface of the sensor unit, place the sensor at distance S. E2CA 73 ...

Page 6

... Compensation for Different Cable Lengths Set the CABLE selector switch to the required position according to the length of the sensor cable being used (9.8 ft (16.4 ft). CABLE 3 m CABLE 3 m M12 Size E2CA-X2A, E2CA-X2A-5M 17 (0.67) across flats 12.5 (0.49) dia. M30 Size E2CA-X10A, E2CA-X10A-5M 36 (1.42) ...

Page 7

... Terminal Arrangement (top view) 35.4 (1.39) Note: The socket can be mounted on DIN Terminal Arrangement (bottom view) PFP-M End Plate E2CA Mounting Holes 40 0.2 (1.57 0.008) rail track or surface mounted using two through holes. Terminal Arrangement (bottom view) Mounting Holes 31 (1 ...

Page 8

... Part Drawing dimension number Y92E-B8 18 0.2 10 max dia. Y92E-B12 24 0.2 12.5 max dia. 37 max E2CA-X2A, Y92E-B18 32 0.2 17 max dia. 47 max E2CA-X5A, Y92E-B30 45 0.2 17 max dia. 60 max E2CA-X10A, M12 Size Sensor E2CA-X2A M30 Size Sensor E2CA-X10A E2CA Panel cutout +0.5 ...

Page 9

... E2CA DETECTING DISTANCE VS. LINEARITY (SQUARE AND RECTANGULAR OBJECTS) M8 Size Sensor E2CA-X1R5A M18 Size Sensor E2CA-X5A DETECTING DISTANCE VS. LINEARITY (CYLINDRICAL OBJECTS) M8 Size Sensor E2CA-X1R5A M12 Size Sensor E2CA-X2A M30 Size Sensor E2CA-X10A M12 Size Sensor E2CA-X2A E2CA M18 Size Sensor E2CA-X5A 77 ...

Page 10

... Note: The illustrations show the terminal arrangement viewed from the rear of the socket that is coupled to the amplifier. DC Amplifier and Sensor CONNECTION OF LINEAR OUTPUT Note: The illustration shows the linear output connected to a resistive load. * Resistance R when E2CA-AL4 is used: 300 Resistance R when E2CA-AN4 is used: 300 78 AC Amplifier and Sensor max ...

Page 11

... Drawing Sensor model dimension E2CA-X1R5A E2CA-X2A mm inch 0. 0.59 20 Tightening Force Do not exceed the maximum torque listed in the table. Sensor model Maximum torque kg-cm E2CA-X1R5A 20 E2CA-X2A 60 E2CA-X5A 150 E2CA-X10A 400 Solid-state load Sink load (photocoupler E2CA-X5A inch mm inch 0. ...

Page 12

... E2CA Panel-Mount Installation Using Y92F-30 Adapter and P3GA-11 Socket Insert the E2CA amplifier through the panel cutout. Push the Y92F-30 adapter from the rear of the amplifier as far forward toward the panel as possible. Then tighten the two retaining screws. Wire the P3GA-11 socket, then push it onto the rear of the amplifier ...

Related keywords