E3HQ-CT12 Omron, E3HQ-CT12 Datasheet - Page 2

no-image

E3HQ-CT12

Manufacturer Part Number
E3HQ-CT12
Description
PTFE HOUSING N.C.
Manufacturer
Omron
Series
E3HQr
Datasheet

Specifications of E3HQ-CT12

Sensing Distance
31.496" (800mm)
Sensing Method
Through-Beam
Output Configuration
NPN - Open Collector/Dark-ON
Mounting Type
Bracket Mount
Current - Supply
40mA
Voltage - Supply
12 V ~ 24 V
Response Time
5ms
Package / Case
Module, Pre-Wired
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E3HQCT12
Ratings and Specifications
Engineering Data (Typical)
Parallel Operating Range
Through-beam
E3HQ-CT1@
Item
Sensing distance
Standard sensing object
Directional angle
Light source (wavelength)
Power supply voltage
Current consumption
Control output
Protection circuits
Response time
Ambient illumination
(Receiver side)
Ambient temperature range Operating: −25 to 55°C, Storage: −30 to 70°C (with no icing or condensation)
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Material
Accessories
−100
−150
150
100
−50
50
0
Case
Cable
Mounting Bracket Stainless steel (SUS304)
Sensing method
0.5
Model
Distance X (m)
1
800 mm
Opaque: 6.25-mm dia. min.
Both Emitter and Receiver 10° to 25°
Infrared LED (950 nm)
12 to 24 VDC±10% including 10% (p-p) max. ripple
40 mA max. (Emitter: 25 mA max., Receiver: 15 mA max.)
Load power supply voltage: 24 VDC max., Load current: 80 mA max. (residual voltage: 1 V max.)
NPN voltage output configuration
Light-ON/Dark-ON (depends on model)
Power supply reverse polarity protection, Output short-circuit protection
Operate or reset: 5 ms max.
Incandescent lamp: 3,000 lx max.
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
20 MΩ min. at 500 VDC
500 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
IP67 (IEC 60529)
Pre-wired cable (standard length: 2 m)
Approx. 100 g
Fluororesin
Fluororesin
Mounting Bracket, 10 Phillips and flat-blade M3 screws, Instruction manual
X
Y
1.5
Excess Gain vs. Set Distance
Through-beam
E3HQ-CT1@
2
500
300
100
0.5
50
30
10
3 times each in X, Y, and Z directions
5
3
1
0
0.5
1
Through-beam
E3HQ-CT1@
1.5
Distance (m)
2.0
E3HQ
2

Related parts for E3HQ-CT12