E5AN-C3MTD-500-N AC/DC24 Omron, E5AN-C3MTD-500-N AC/DC24 Datasheet - Page 60

no-image

E5AN-C3MTD-500-N AC/DC24

Manufacturer Part Number
E5AN-C3MTD-500-N AC/DC24
Description
Multi-input 1/4 Din TC New08
Manufacturer
Omron
Datasheet

Specifications of E5AN-C3MTD-500-N AC/DC24

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
60
E5@N/E5@N-H
Parameters
Basic Type
Some parameters are not displayed depending on
the model of the Controller and parameter settings.
For details, refer to the E5CN/E5AN/E5EN Digital
Temperature Controllers User's Manual Basic Type
(Cat. No. H156).
C
C
C
Adjustment
Level
l.adj
lcr1
C
lcr2
sp-0
sp-2
sp-3
cmwt
sp-1
ct1
hb1
oc1
ct2
hb2
oc2
hs1
M
hs2
50.0
50.0
50.0
50.0
off
off
0.0
at
0.0
M
M
M
M
0.0
M
M
M
M
M
M
0.0
0.0
0.0
0.0
M
M
M
M
M
M
0
0
0
0
Heater Burnout
Detection 1
Communications
Writing
Heater Current 1
Value Monitor
Heater Overcurrent
Detection 1
Leakage Current 1
Monitor
Adjustment Level
Display
Displayed only
once when
entering
adjustment level.
AT Execute/Cancel
Heater Current 2
Value Monitor
Heater Burnout
Detection 2
Heater Overcurrent
Detection 2
HS Alarm 1
Leakage Current 2
Monitor
HS Alarm 2
SP 3
SP 0
SP 1
SP 2
SP used by
multi-SP
Press the O Key less than 1 s.
Press the O Key less than 1 s.
Press the PF Key for
at least 1 s. ✽1
C
C
C
C
C
C
C
C
C
insh
c-db
of-r
mv-s
ol-h
c-sc
chys
wt-b
mv-e
sqrp
insl
soak
ol-l
sprt
105.0
ins
hys
orl
233
50.0
-5.0
off
M
M
M
M
M
M
M
M
M
M
off
M
M
M
M
M
M
M
0.0
0.0
0.0
8.0
0.0
1.0
1.0
0.0
0.0
0.0
0.0
M
M
M
40
d
p
i
1
Temperature Input Shift
Hysteresis (Heating)
Upper Limit
Temperature
Input Shift Value
Cooling Coefficient
Dead Band
Manual Reset Value
Clear the offset during
stabilization of P or PD
control.
Hysteresis (Cooling)
Soak Time
SP Ramp Set Value
Lower Limit
Temperature
Input Shift Value
Proportional Band
Integral Time
Wait Band
MV at PV Error
MV Upper Limit
MV Lower Limit
Derivative Time
MV at Stop
Extraction of Square Root
Low-cut Point
MV Change Rate Limit
Hysteresis settings
Heating/cooling
PID settings
1-point shift
2-point shift
Starting in manual mode.
Set either
of these
parameters.
Press the
O Key
for at
least 3 s.
Press the O and M Keys for
at least 3 s.
PV/MV
C
Manual Control Level
Note: The time taken to move to the protect
prlp
pfpt
pmsk
pmov
oapt
icpt
wtpt
25
M
C
C
C
level can be adjusted by changing the
"Move to protect level time" setting.
off
off
m-sp
lcr1
lcr2
M
M
M
M
on
M
M
sp-m
sktr
prst
1
0
0
0
a-m
ct1
ct2
Protect Level
PID
Control
only
rset
25
25
Initial Setting/
Communications Protect:
This protect level restricts movement
to the initial setting, communications
setting, and advanced function setting
levels.
Password to Move to Protect Level:
Password setting
Setting Change Protect:
Protects changes to setups by
operating the front panel keys.
PF Key Protect
Restricts PF key operation
(E5AN/E5EN only)
Parameter Mask Enable:
Displayed only when a
parameter mask is set.
M
M
0.0
M
0.0
M
0.0
M
0.0
M
M
M
Move to Protect Level:
Displayed only when a password
is set. Restricts moving to protect
level.
Operation/Adjustment Protect:
Restricts displaying and
modifying menus in operation,
adjustment, and manual control
levels.
M
M
M
0
0
0
0
Leakage Current 2
Monitor
Power ON
Auto/Manual Switch
PID control only.
Added when
auto/manual select
addition is ON.
Multi-SP
Set Point Setting
Set Point During
SP Ramp
Heater Current 1 Value
Monitor
Leakage Current 1
Monitor
Soak Time Remain
Program Start
Process Value/
Set Point
Heater Current 2 Value
Monitor
Process Value
Added when Additional
PV display is ON.
Press the O
Key or the PF
Key for at least
1 s.
✽1
Operation Level
Press the O and M Keys for at least 1 s.
Note: Displayed only for models with communications.
Starting in
automatic
mode.
C
C
C
C
C
C
C
C
C
Communications
Setting Level
al-1
al-2
al-3
al1h
al2h
al3h
al1l
al2l
al3l
r-s
c-o
run
prty
Changes are effective after cycling power or
after a software reset.
u-no
sbit
sdwt
M
psel
M
M
M
M
M
M
M
M
M
0.0
M
0.0
M
o
len
even
0
0
0
0
0
0
0
0
bps
0
cwf
M
M
M
M
M
M
M
9.6
RUN/STOP
Alarm Value 1
Alarm Value
Upper Limit 1
MV Monitor (Cooling)
20
Alarm Value
Lower Limit 1
Alarm Value 2
Alarm Value 3
Alarm Value
Upper Limit 3
Alarm Value
Lower Limit 3
MV Monitor (Heating)
Alarm Value
Lower Limit 2
Alarm Value
Upper Limit 2
1
7
2
Communications Unit No.
Protocol Setting:
Switches between
CompoWay/F (SYSWAY)
and Modbus.
Communications
Data Length
Communications
Stop Bits
Communications Parity
Communications
Baud Rate
Send Data Wait Time
Press the O Key for at least 3 s.
Other than the Auto/Manual Switch display
CompoWay/F
(SYSWAY) only
Press the O Key
less than 1 s.
Press the
O Key for
at least 1 s.
PF Key ✽2
✽1. When the PF Setting
✽2. When the PF Setting
Initial Setting Level
parameter is set to A-M for a
Controller with a PF Key
(E5AN/E5EN).
parameter is set to PFDP for a
Controller with a PF Key
(E5AN/E5EN).
Press the O Key less than 1 s.
C
C
C
alt1
alh1
in-h
sl-h
ptrn
c-cp
s-hc
in-t
in-l
sl-l
cntl
orev
d-u
1300
onof
stnd
or-r
100
dp
off
cp
M
M
M
M
M
M
M
M
M
st
M
M
M
M
M
M
M
0.2
20
on
20
0
5
0
c
2
Control Period (Heating)
Input Type
Scaling Upper Limit
Scaling Lower Limit
Decimal Point
Temperature Unit
SP Upper Limit
PID ON/OFF
Program Pattern
Control Period (Cooling)
Alarm 1
Hysteresis
ST (Self-tuning)
Direct/Reverse Operation
Alarm 1 Type
SP Lower Limit
Standard or
Heating/Cooling
C, F
When assigning PID or
control output to ON/OFF
output
For input type of analog
PF Key
Set the ON/OFF
output cycle.
For input type of
temperature, standard
control, or PID
Limit the set point
For input type of
temperature
✽2

Related parts for E5AN-C3MTD-500-N AC/DC24