Name and function of each part
Sensor: Z300-S5T/-S10/-S60
Controller: Z300-VC10V3/Z300-VC15V3
(3) Wire the ground wire.
(4) Connect to the power supply unit.
(5), (6) Connect to a programmable controller or other external device.
(7) Connect the monitor.
(8) Connect the console.
(9) Connect the sensor.
(10) Connect if using an analog output.
C-40
Sensor: Z300-S2T
(14) STAB indicator
(13) DARK indicator
(15) BRIGHT indicator
(12) RS-232C
connector
2-M2×4
(11) DIP switch
Using Z300-S2T
When you remove and measure a beam cover, please attach the monitor
cap attached to the sensor in the position of the following figure.
When you display a circumference image, please be sure to attach a
beam cover. Where a beam cover is removed, a circumference image
cannot be displayed correctly.
(3) Emitter
For more Information: U.S. www.sensors.omron.com
(4) Receiver
Lever
screw M2 x 5
Mounting a beam cover
* Not used.
(10) Analog output
terminal
(3) Ground
terminal
~
(1) NEAR indicator
(2) FAR indicator
(7) Beam cover
(6) Monitor
(3) Emitter
(5) Lighting
~
(1) NEAR indicator
(2) FAR indicator
~
(4) Receiver
Demounting a beam cover
(4) Power
terminal
~
(9) Sensor connector
~
~
~
~
~
~
Monitor cap (accessory)
~
(5) Output
terminal
~
(5) Output terminal
~
~
~
(1), (2) When the distance from the sensor front to the work is within the measurement
range, these lamps illuminate in response to the distance.
If the work is outside the measurement range or there is insufficient light, both lamps will
blink.
This indicator lamp also functions as a laser emission warning light.
• Immediately after turning on the power, at least one of the indicator lamps will illuminate
steadily or blink.
• During the first 15 to 25 seconds after turning on the power, both indicator lamps will re-
• During laser emission, one of the indicator lamps will illuminate steadily or blink.
• When the laser is off, both indicator lamps will be off.
(3) Laser projector
(4) Laser receiver
(5) Illumination for display of peripheral images.
(6) Load a peripheral image.
(7) Switch from measurement to peripheral image display, and then from peripheral image
~
~
main off, indicating that the laser light is off.
~
~
display to measurement. To display a peripheral image, loosen the screw on the beam
cover lever and then move the lever to the left. To switch to measurement, move the le-
ver to the right. The lever screw should be tightened to a torque of 1.5 to 3 kgf²cm using
a slotted screwdriver.
~
~
~
~
~
~
~
~
~
measurement range
~
~
~
Outside of the
~
~
(6) Input terminal
(11) Set if using in NON VISUAL mode.
(12) Connect to a computer, programmable controller, or other external device.
(13), (14), (15) Illuminates according to the light intensity in the sensor unit.
If LDOFF is input from the terminal block or RS-232C, or the sensor is not con-
nected, all indicator lamps will blink.
• BRIGHT indicator lamp: Illuminates when the light intensity is too high.
• DARK indicator lamp: Illuminates when the light intensity is too low.
• STAB indicator lamp: Illuminate when the light intensity is suitable.
~
~
Z300-S2T
Z300-S5T
Z300-S10
Z300-S60
~
~
~
~
~
~
~
~
~
~
* Please do not open here.
Measurement range
250
19
45
80
minimum value
(8) Console connector
Canada www.sensors.omron.ca
Measurement center distance
* Please do not remove the
seal of the side.
19.9
49.5
565
98
(2) FAR indicator
(1) NEAR indicator
(7) Monitor connector
100
600
20
50
Measurement range
If the lid of the portion of
is lifted, a terminal will appear.
maximum value
20.1
50.5
102
635
Circumference image display
Measuring
(Unit: mm)
120
950
21
55
Outside of the
sensing range
Lever
Lever
NEAR indicator
FAR indicator
Lit
Flashing
Not lit