Specifications of G2AK-232A-US-AC100

Relay Type
General Purpose
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
0.5A @ 24VDC
Coil Type
Latching, Dual Coil
Coil Current
18.5mA
Coil Voltage
100VAC
Control On Voltage (max)
80 VAC
Mounting Type
Socket
Termination Style
Socketable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
 Details
Other names
G2AK232AUSAC100
G2AK232AUSAC100NC
Safety Precautions
Refer to Safety Precautions for All Relays.
The G2AK can be used for special purposes by utilizing its built-in diodes.
When built-in diodes are not required
When built-in diodes are required
Examples of built-in diode applied circuit
Circuits
Do not allow voltage to be applied simultaneously to both the
set and reset coil. If voltage is applied simultaneously, the
operation will become unstable.
Note: If a smoothing capacitor is used as shown on the right, the
With the DC-coil Latching Relay, the built-in diode(s) can be
used for surge absorption. in this case, pay attention to the
polarity of the coil. Note that the 5-minute rating applies only to
the set coil rated at 6 VDC and the continuous rating for other
DC coil voltages remains unchanged.
With the DC/AC-coil Latching Relay, if the junctions between the
set coil and built-in diode and between the reset coil and built-in
diode are connected as shown on the right, only one of the
built-in diode is required and the rest of the diodes become
unnecessary. However, a coil operating switch is required for
each coil. In this case, because of the diode characteristics, the
load rating must be 0.5 A or less.
When using the AC-coil Latching Relay which operates on
commercial AC input, the built-in diodes are required.
With the DC/AC-coil Latching Relay, the built-in diodes are
required for an inductive electrical equipment circuit which
consists of two or more set/reset coils, motor M, general
electromagnetic coil X, etc. per coil operating switch as shown
on the right.
With the DC-coil Latching Relay, the built-in diodes become
unnecessary for a circuit in which a coil operating switch is
incorporated for each of the set and reset coils as shown on the
right.
With the AC-coil Latching Relay, a half-wave rectified power
supply can be obtained as shown on the right. This can be
used as a power supply for light-emitting diodes. However,
because of the diode characteristics, the load rating must be
0.5 A or less.
waveform of the current that flows into the set or reset coil
changes from half wave to that of nearly direct current. In
other words, ripple is improved but the coil temperature
rises, which may adversely affect the set or reset voltage.
Therefore, avoid circuit configuration with an electronic
device which improves ripple, such as a capacitor.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
http://www.ia.omron.com/
In the interest of product improvement, specifications are subject to change without notice.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Set or reset coil
Set or reset coil
Set or reset coil
Built-in diode
of G2AK
(+)
* EMR: General-purpose electromagnetic relay
The figures above represent the terminal num-
bers. The figures in parentheses represent the
terminals on the set side.
*
5 (8) 13 (14)
Unwanted diodes
*
Unwanted diodes
Set or reset
coil of
G2AK
Lamp
Smoothing
capacitor
X
See note below.
Coil
or
EMR*
G2AK