Specifications of G3J-T217BL-C AC100-240

Circuit
SPST-NO (1 Form A)
Output Type
AC
Load Current
17.4A
Voltage - Input
75 ~ 264VAC
Voltage - Load
180 ~ 264 V
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3J-T217BL-CAC100-240
G3JT217BLCAC100240
G3JT217BLCAC100240NC
New Models with AC Power Supply Input and
Monitor Output Equivalent to Non-contact
SPST-NO Join the G3J-T Series
• Limiting the starting current saves energy.
• Certified for UL and CSA.
• Mounts with screws or to DIN Track.
• Compact design with heat sinks (3.7-kW models: 100 × 100 ×
• Built-in snubber circuit and thyristor.
• Built-in operation indicator.
Appearance
Ordering Information
■ List of Models
■ Accessories (Order Separately)
Mounting Bracket
Note: Use this Bracket when mounting Thermal Relay GTK-22 (LS Industrial Systems) to a G3J-series.
3
Number of
R99-14 FOR G3J (See note.)
130 mm (W × H × D)).
elements
Solid State Contactor for 3-phase Motors with Built-in Soft Start/Stop and Monitor Output
G3J-T-C
Operation indicator
Input terminals
Refer to Safety Precautions for All Solid State
Relays.
Model
Phototriac
coupler
Isolation
method
100 to 240 VAC
12 to 24 VDC
supply voltage
Rated power
No-voltage input
(open and short-
circuited input)
Input method
Output terminals (power supply side)
Monitor output terminals
Starting torque adjuster (default setting: 200%)
Ramp-up time adjuster (default setting: 1 s)
Ramp-down time adjuster (default setting: 1 s)
Output terminals (load side)
3.7 kW (17.4 A)
2.2 kW (11.1 A)
0.75 kW (4.8 A)
3.7 kW (17.4 A)
2.2 kW (11.1 A)
0.75 kW (4.8 A)
Applicable monitor capacity
(AC3)
200 to 220 VAC AC
switching
output
DC
switching
output
Monitor
output
G3J-T217BL-C AC100-240
G3J-T211BL-C AC100-240
G3J-T205BL-C AC100-240
G3J-T217BL-C DC12-24
G3J-T211BL-C DC12-24
G3J-T205BL-C DC12-24
CSM_G3J-T-C_DS_E_3_1
Model
1

Related parts for G3J-T217BL-C AC100-240

G3J-T217BL-C AC100-240 Summary of contents

Page 1

... No-voltage input 3.7 kW (17.4 A) 200 to 220 VAC AC (open and short- 2.2 kW (11.1 A) circuited input) 0.75 kW (4.8 A) 3.7 kW (17.4 A) 2.2 kW (11.1 A) 0.75 kW (4.8 A) CSM_G3J-T-C_DS_E_3_1 Monitor Model output G3J-T217BL-C AC100-240 switching G3J-T211BL-C AC100-240 output G3J-T205BL-C AC100-240 DC G3J-T217BL-C DC12-24 switching G3J-T211BL-C DC12-24 output G3J-T205BL-C DC12-24 1 ...

Page 2

... SSR input turned ON: Maximum residual voltage between short-circuited terminals SSR input turned OFF:Maximum leakage current of 0.15 mA Relay input: For minute signals G3J-T211BL-C G3J-T205BL-C 4.8 A (at 40°C) 150 A (60 Hz, 1 cycle 57 200 to 220 VAC 0.75 kW (4.8 A) 200 to 240 VAC 4 ...

Page 3

... Ambient operating humidity Weight Note: 1. Provided that the starting torque is 600% In when the motor is started at full voltage. 2. The monitor output will be ON while load current is flowing to the main circuit. Connections ■ Connection Examples AC Model G3J-T@BL-C Three-phase, 200 to 220 V L1/R L2/S L3/T 1 ...

Page 4

... T1/U T2/V T3/W Thermal Relay M Motor Note: Be sure to use a fuse or non-fuse breaker to protect the G3J. Time Chart Example Reversible contactor Forward rotation signal input (output form PLC) Reversible contactor Reverse rotation signal input (output from PLC) G3J-T-C Input signal (output from PLC) ...

Page 5

... Ramp-up time = 1 s Starting torque = 450% In Testing for the soft start/stop model was performed at the following conditions: Ramp-up time = 1 s Ramp-down time = 1 s Starting torque = 450% In G3J-T-C G3J-T217BL-C G3J- T211BL-C 200 300 400 Overload current (Arms) AC53-2: 6-6: 25-15, Actual Load Service Life Test ...

Page 6

... Ramp-up time adjuster Monitor output Two, M3 × 8 Output terminals Six, M4 × 8 4.6 × 5.6 5.5 Oval hole 7.6 13.2 13.2 Ramp-down time adjuster 80 max. G3J-T-C Ramp-down time Monitor output release time Mounting Hole Dimensions Two, 4.5-dia holes 90 50 ±0.2 120 max. ±0.2 6 ...

Page 7

... In the interest of product improvement, specifications are subject to change without notice. 15.85 44.9 37.1 4.6 dia. 50 Stating torque adjuster Ramp-up time adjuster Output terminals 5.5 Six, M4 × 8 4.6 × 5.6 7.6 Oval hole 13.2 13.2 100 max. Ramp-down time adjuster G3J-T-C Mounting Hole Dimensions Two, 4.5-dia holes 50 ±0.2 130 max. 90 ±0.2 7 ...

Page 8

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords