G3MC-201PL DC5 Omron, G3MC-201PL DC5 Datasheet
![SOLID STATE RELAY](/photos/9/55/95578/g3mc_sml.jpg)
G3MC-201PL DC5
Specifications of G3MC-201PL DC5
G3MC-201PL-DC5
G3MC201PLDC5
Z2521
Related parts for G3MC-201PL DC5
G3MC-201PL DC5 Summary of contents
Page 1
... Compact, thin--profile SSR of monoblock construction D with an all--in--one frame incorporates a PCB, terminals, and a heatsink. VDE certified models available. D Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G3MC-101P-DC12). Isolation Zero-cross function Built-in snubber circuit Phototriac Yes Yes ...
Page 2
... VAC G3MC-201P(L) 100 to 240 VAC G3MC-102P(L) 100 to 120 VAC G3MC-202P(L) 100 to 240 VAC J CHARACTERISTICS Item G3MC-101P / G3MC-102P Operate time 1/2 of load power source cycle + 1 ms Release time 1/2 of load power source cycle + 1 ms) Output ON voltage drop 1.6 V (RMS) max. ...
Page 3
... Engineering Data J G3MC-101P(L), G3MC-201P(L) Load Current vs. Ambient Temperature Characteristics Ambient temperature (°C) J G3MC-102P(L), G3MC-202P(L) Load Current vs. Ambient Temperature Characteristics 2.5 2.0 1.5 1.0 0 - Ambient temperature (°C) Inrush Current Resistivity One cycle, non-repetitive (Keep the inrush current to half the rated value if it occurs repeatedly.) ...
Page 4
... Dimensions Unit: mm (inch) G3MC-101P G3MC-101PL G3MC-201P G3MC-201PL 13.5 max. G3MC-102P G3MC-102PL G3MC-202P G3MC-202PL 0.8. (0.03) 20.5 max. (0.81 3.5 (0.14) Four, 1.6 (0.06) 2.54 (0.10) G3MC 4 Solid State Relay 4.5 max. 24.5 max. 4.50 max. (0.18) 24.5 max. (0.97 0.25 Four, 0.7 (0 ...
Page 5
... If Units are closely mounted and used in places with no ventilation, the load current of each Unit must be 1/2 of the rated load current. J PROTECTIVE ELEMENT No overvoltage absorption element is built in. Therefore, if the G3MC is connected to an inductive load, be sure to connect the overvoltage absorption element. G3MC Solid State Relay 5 ...
Page 6
... Use with Attention: The followings are some examples of applications for which particular attention must be given. This is not intended exhaustive list of all possible use of any Product, nor to imply that any use listed may be suitable for any Product: G3MC 6 Solid State Relay (a) Outdoor use, use involving potential chemical contamination or electrical interference ...
Page 7
... European Union’s Directive on the Restriction of certain Hazardous Substances (“RoHS”), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information. G3MC Solid State Relay 7 ...
Page 8
... To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. J01C-E-01 01/07 G3MC 8 Solid State Relay Specifications subject to change without notice OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca ...