G6HK-2-DC6 Omron, G6HK-2-DC6 Datasheet

LOW SIGNAL RELAY

G6HK-2-DC6

Manufacturer Part Number
G6HK-2-DC6
Description
LOW SIGNAL RELAY
Manufacturer
Omron
Series
G6Hr
Datasheet

Specifications of G6HK-2-DC6

Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Type
Latching, Dual Coil
Coil Current
33.3mA
Coil Voltage
6VDC
Control On Voltage (max)
4.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
2 Form C
Power Consumption
200 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6HK-2-DC6
G6HK2DC6
Z2544

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6HK-2-DC6V
Manufacturer:
OMRON
Quantity:
15 000
Ultra-compact, Ultra-sensitive DPDT Relay
• Compact size and low 5 mm profile.
• Low thermoelectromotive force.
• Low magnetic interference enables high-density mounting.
• Utilizes Omron’s moving-loop design.
• Highly stable magnetic circuit for latching endurance and
• High sensitivity with low nominal power consumption.
• Single or dual coil latching types available.
• RoHS Compliant
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6H-2-DC6).
■ Non-latching
■ Latching
Specifications
■ Contact Data
Note: P level:
Through-hole
Surface mount
Through-hole
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load (See note)
excellent resistance to vibration and shock.
Low Signal Relay
G6H
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary
depending on the operating environment. Always double-check relay suitability under actual operating conditions.
λ
Terminal Type
Terminal Type
60
= 0.1 x 10
Load
–6
/operation
DPDT
DPDT
DISCONTINUED
0.50 A at 125 VAC, 1 A at 30 VDC
Ag (Au clad)
1 A
125 VAC, 110 VDC
1 A
62.50 VA, 33 W
10 μA, 10 mVDC
Contact form
Contact form
Resistive load (p.f. = 1)
G6H-2
G6H-2F
G6HU-2
Single coil latching
Low Signal Relay
Model
Model
G6HK-2
G6H
Dual coil latching
R
C
49

Related parts for G6HK-2-DC6

G6HK-2-DC6 Summary of contents

Page 1

... Always double-check relay suitability under actual operating conditions. DISCONTINUED Contact form G6H-2 G6H-2F Contact form Single coil latching G6HU-2 Resistive load (p. 0. 125 VAC VDC Ag (Au clad 125 VAC, 110 VDC 1 A 62.50 VA μA, 10 mVDC Low Signal Relay C R Model Model Dual coil latching G6HK-2 G6H 49 ...

Page 2

... Rated voltage Rated current Coil (VDC) (mA) resistance (Ω) 3 33. 250 6 16.70 360 9 11.10 810 12 8.30 1,440 24 6.25 3,840 Dual Coil Latching Type (G6HK-2) Rated voltage Rated current Coil (VDC) (mA) resistance (Ω) 3 66. 125 6 33.30 180 9 22.20 405 12 16.70 720 24 12.50 1,920 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23° ...

Page 3

... The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength. (The insulation resistance between the set and reset coil (G6HK-2), however, is 100MΩ min. when measured with a 125-VDC megohmmeter). 4. The above values are initial values. ...

Page 4

... Condition: The Units were shocked at the rate of 500 m/s three times each in the ±X, ±Y, and ±Z directions with and without voltage imposed on the Units until the Units malfunctioned. 30-VDC resistive load Dual Coil Latching (G6HK- VDC 24 VDC Ambient temperature (°C) 2 ...

Page 5

High-frequency Characteristics (See notes 1 and 2.) Frequency vs. Isolation (Average value) 0 Unit: G6H-2 Unit: G6H-2 Number of Units 100 100 200 500 1,000 Frequency (MHz) Distribution of Operate and Release Time (See note ...

Page 6

... G6H-2F 14.3 max. (14.1)* 6.6 max. (6.3)* ■ Latching G6HU-2 14.3 max. (14.1)* 0.25 5.4 max. (5.0)* 3.5 2.54 G6HK-2 14.3 max. (14.1)* 0.25 5.4 max. (5.0)* 3.5 2.54 G6H 54 Low Signal Relay DISCONTINUED Terminal Arrangement/ Internal Connections 9.3 max. ...

Page 7

Hints on correct use Example of Recommended Soldering Conditions for the G6H-2F (Surface Mount Relays) (1) IRS Method (Mounting Solder: Lead) Soldering 220 to 240 180 to 200 Preheating 150 90 to 120 Time (s) Note: The ...

Page 8

Precautions Long-term Continuously ON Contacts Using the Relay in a circuit where the Relay will be ON continuously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, ...

Page 9

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 10

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...

Related keywords