K8AB-AS1 100/115VAC Omron, K8AB-AS1 100/115VAC Datasheet
K8AB-AS1 100/115VAC
Specifications of K8AB-AS1 100/115VAC
K8ABAS1100115VAC
Z2803
Related parts for K8AB-AS1 100/115VAC
K8AB-AS1 100/115VAC Summary of contents
Page 1
... AC/DC 100 mA AC/DC 500 mA AC/ AC/DC, 0 AC/DC, 0 AC/ 100 A AC 200 A AC (See note.) Note: The K8AB-AS3 is specially designed to be used in combination with the OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not possible.) 4. Supply Voltage 24 VAC/DC: 24 VAC/DC 100-115 VAC: 100 to 115 VAC ...
Page 2
... A AC/DC I3-COM K8AB-AS3 0 to 100 A AC I2-COM 0 to 200 A AC I3-COM Note: The K8AB-AS3 is designed to be used in combination with an OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not possible.) * The range is selected using connected terminals. Supply voltage Model 24 VAC/DC K8AB-AS1 24 VAC/DC 100-115 VAC ...
Page 3
... K8AB-AS1 AC/ 100 mA AC/ 500 mA AC/DC K8AB-AS2: 0 AC/DC 0 AC/DC 0 AC/DC K8AB-AS3: When used together with a K8AC-CT200L Current Transformer 10 to 100 200 A AC 100% operation at set value 5% to 50% of operating value Manual reset/automatic reset (switchable) Note: Manual reset: Turn OFF power supply for longer. ...
Page 4
... Hz ±5 Hz K8AB-AS1 and K8AB-AS2: DC input or AC input ( Hz) K8AB-AS3: AC input ( Hz) K8AB-AS1 and K8AB-AS2: Continuous input: 120% of maximum input max.: 150% of maximum input. K8AB-AS3: Continuous input: 120% of maximum input max.: 200% of maximum input max.: 600% of maximum input Note: Overload capacity of primary side of CT. ...
Page 5
... Load Load Note: 1. The K8AB-AS3 is designed to be used in combination with the OMRON K8AC-CT200L Current Transformer (CT). 2. There is no polarity when a DC current input is used. 3. Refer to the “Setting Ranges and Wiring Connections” as the explanation of current input l1, l2, and l3 terminal. ...
Page 6
... Al 1,5-8BK (for AWG16) • Al 1-8RD (for AWG18) • Al 0,75-8GY (for AWG18) 2. Tightening torque Recommended: 0.49 N·m Maximum: 0.54 N·m K8AB-AS Meaning Lit when power is being supplied. Lit when relay is operating. undercurrent. The indicator flashes to indicate the error status after the input has exceeded the threshold value while the operating time is being clocked ...
Page 7
... Wiring connection I1-COM I2-COM I3-COM I1-COM I2-COM Note: 1. The DC input terminals have no polarity. I3-COM 2. The K8AB-AS3 is designed to be used in combination with I2-COM the OMRON K8AC-CT200L Current Transformer (CT). (Direct input is not possible.) I3-COM DIP Switch Functions SWITCH ON ● ↑ ON OFF ❍ ↓ ...
Page 8
... Startup lock timer start (Unit: mm) 5 100 Mounting Hole Dimensions Two M5 screw holes or two 5.5-dia. holes 76 30 dia. Note: The OMRON Current Transformer (CT) is designed to be used with the K8AB-AS3. Use terminals k and l for connections. (Terminals kt and lt are not used.) 8 ...
Page 9
... K8AB will (i.e loops startup current of six times the rated current is generated, it will be 150 A (i.e 6). The overload capacity for the K8AB-AS3 is 200% of the rating for 30 s. The Relay will not fail even if the startup current continues for 30 s, and it is possible to perform overload detection ...
Page 10
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...