MJN3CF-DC12 Omron, MJN3CF-DC12 Datasheet - Page 3

G.P. RELAY

MJN3CF-DC12

Manufacturer Part Number
MJN3CF-DC12
Description
G.P. RELAY
Manufacturer
Omron
Series
MJNr
Datasheets

Specifications of MJN3CF-DC12

Relay Type
General Purpose
Contact Form
3PDT (3 Form C)
Contact Rating (current)
10A
Switching Voltage
600VAC, 28VDC - Max
Coil Type
Standard
Coil Current
100mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .187" (4.7mm)
Circuit
3PDT (3 Form C)
Contact Rating @ Voltage
10A @ 28VDC
Control On Voltage (max)
9 VDC
Contact Rating
10 A
Contact Termination
Plug In
Mounting Style
Flange
Power Consumption
1.2 W
Contact Material
Silver Alloy
Coil Resistance
50 m Ohms
Current, Rating
10 A
Dielectric Rating
750 VAC
Dimensions
1.525 in. L x 1.400 in. W x 1.905 in. H
Function
General Purpose
Material, Contact
3⁄16in. Dia. Ag-Alloy
Power, Rating
2400⁄280 VA⁄W
Resistance, Coil
120 Ohms +⁄- 10%
Standards
UL, CSA
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-45 °C
Termination
Plug-In
Voltage, Control
12 VDC
Voltage, Rating
240 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
MJN3CFDC12
Z241
Latching - - DC
Note: 120% of nominal or greater (one second duration single pulse) unlatch voltage — above this the relay latches again.
J CHARACTERISTICS
Note: A latch pulse of 50 ms minimum at nominal voltage is recommended to insure positive latching.
Nominal
voltage
5 VDC
6 VDC
12 VDC
24 VDC
48 VDC
110 VDC
Operate time
Release time
Latch time
Unlatch time
Operating
ambient
temperature
temperature
Insulation material
Duty cycle
Shock
Vibration
Life expectancy
Dielectric strength
Terminals
Weight
p
bi
Maximum continuous voltage: 120% of nominal (one coil only)
g
Latch coil
resistance in
Ohms ±10%
14
20
80
330
1290
5125
AC: 1 & 2 pole
AC: 3 pole
DC: 1, 2 & 3
pole
l
,
p
p
Unlatch coil
resistance in
Ohms ±10%
45
64
275
1070
2850
10750
Operating
Storage
Operating
Storage
Operating
Storage
Electrical at
rated load
Mechanical
Nominal coil power
1.2 W
15 ms nominal; 20 ms maximum
6 ms nominal; 10 ms maximum
13 ms nominal with a one second pulse of nominal voltage (See note)
13 ms nominal with a one second pulse of nominal unlatch voltage after latching with
a one second pulse of nominal latching voltage. (See note)
- -45_ to 60_C (- -49_ to 140_F)
- -65_ to 100_C (- -85_ to 212_F)
- -45_ to 45_C (- -49_ to 113_F)
- -65_ to 100_C (- -85_ to 212_F)
- -45_ to 70_C (- -49_ to 158_F)
- -65_ to 100_C (- -85_ to 212_F)
High quality phenolic
Rated for continuous duty operation at 25% overvoltage
15 g’s 11±1ms (non-operating test, no mechanical damage)
0.1” DA or 10 g’s, 10 to 55 Hz (operating test, no contact chatter)
100,000 operations
10,000,000 operations
Greater than 750 VAC, RMS 60 Hz across open contacts
Greater than 2500 VAC, RMS 60 Hz all other mutually insulated elements
Quick connect
64 g (2.3 oz) open relay
84 g (3.0 oz) enclosed relay
Coil
voltages
5 to 110 VDC
General Purpose Relay
Insulation
resistance
1000 MΩ
min. @ 500
VDC
VDC
i
@ 00
Operate voltage
(latch/unlatch) at
25_C (77_F)
(See note)
75% of nominal
MJN