MM2XP AC200/(220) Omron, MM2XP AC200/(220) Datasheet
MM2XP AC200/(220)
Specifications of MM2XP AC200/(220)
MM2XPAC200220NC
Related parts for MM2XP AC200/(220)
MM2XP AC200/(220) Summary of contents
Page 1
Power Relay MM Stable Contact Reliability and Long Life • Easy to mount, wire, and use. • A large selection of models including various contact forms, DC-switching models, and open models. • Mechanical life: 5,000,000 operations; electrical life (under rated ...
Page 2
... Example: MM2, 6 VAC Rated coil voltage 2. Latching Relays based on the MM Series are also available. Refer to the MMK. 3. Models with built-in varistors (AC operation) are also available in addition to those with built-in diodes. Ask your OMRON repre- sentative for details. Contact form Relay model ...
Page 3
Model Number Legend MM@@@@-@ Contact Form 2: DPDT 3: 3PDT 4: 4PDT 2. Type (See Note.) None: Standard X: DC-switching 3. Terminal Shape None: Solder B: Screw P: Plug-in ■ Accessories (Order Separately) Mounting ...
Page 4
Specifications ■ Coil Ratings Open Coils (with Solder or Screw Terminals) Rated voltage Rated current (mA) ( 790 655 1,120 12 395 325 560 24 195 160 280 134 100/(110) ...
Page 5
Coils (Conforming to Auxiliary Power Relay Specifications) Rated voltage Rated current (mA) (V) tance (Ω 245 210 8.5 50 117 102 36 100/(110) 58.5 51/58 150 110 53 46 182 115 51 44 210 ...
Page 6
Contacts (Conforming to Auxiliary Power Relay Specifications) Item Resistive load Contact type Single Contact material Ag Rated load 220 VAC VDC Rated carry current 5 A Max. switching voltage 250 VAC, 250 VDC ...
Page 7
Relays (Conforming to Auxiliary Power Relay Specifications) Item Contact resistance (See note 2.) 50 mΩ max. Operate time (See note 3.) AC max., DC max. Release time (See note 3 max. Max. operating frequency ...
Page 8
Endurance Curves Open Relays MM@(B) 10,000 7,000 5,000 220 VAC resistive load 3,000 inductive load (cosφ = 0.4) 1,000 24 VDC 700 resistive load 500 inductive load L 300 100 Switching current (A) ■ DC-switching Relays Maximum ...
Page 9
Relays Conforming to Auxiliary Power Relay Specifications Maximum Switching Power MM4P-JD AC resistive load AC inductive load cosφ = 0.4 DC resistive load DC inductive load L Switching voltage (V) Endurance Curves MM4P-JD 220 VAC: resistive ...
Page 10
Ambient Temperature vs. Must-operate and Must-release Voltage MM2P AC (60 Hz) Number of Relays: 5 Must-operate voltage Must-release voltage Ambient temperature (°C) Ambient Temperature vs. Coil Temperature Rise MM2P 110 VAC (60 Hz) Contact carry current Number of Relays: 5 ...
Page 11
Relay Mounting Adjacent Distance vs. Coil Temperature Rise MM4P 100 /(110) VAC Relay mounting Upper position Condition: The saturated coil temperature is measured with the rated carry current (7 the rated coil voltage (100 VAC at 50 Hz). ...
Page 12
Mounting Holes (Bottom View) Direct mounting Four, 4.5-dia. mounting holes Length of l 22±0.2 DPDT: 22±0.2 3PDT: 28±0.2 4PDT: 34±0.2 Mounting Bracket (S Bracket) R99-03 (S KANAGU) FOR MM@ The S Bracket can be used to mount a Relay with ...
Page 13
Cased Relays Plug-in Terminals MM2P(N, -D) MM2XP(N, -D) MM2P Note: As shown in the diagram, there are three 10-dia. holes in the side of the case for the MM2XP(N, -D). When a case-protection plate is attached, the width of the ...
Page 14
MM3PXP(N) MM4P(N, -D) MM4XP(N, -D) 80.5 59.5 max. max. MM4P 79.5 max. (See note 2.) Note 1: As shown in the diagram, there are three 10-dia. holes in the side of the case for MM@XP(N, -D). 2: When a case-protection ...
Page 15
MM4P-JD 70.5 max. 59.5 max. 79.5 max. MM4XP-JD 70.5 max. 59.5 max. 80 max. ■ Relays with Operation Indicators Dimensions are the same as those for standard Relays except that there are three 10-mm holes in the case as shown ...
Page 16
Height with Socket DIN Track/Front-connecting Socket MM2(X)P 95.5 MM3P 113 92 109.5 113.5 8PFA 11PFA Safety Precautions Refer to Safety Precautions for All Relays. ■ Connection • Use proper crimp terminals or 1.2- to 2-mm-dia. single-conductor wire to connect screw ...
Page 17
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...