PYF14A-E-US Omron, PYF14A-E-US Datasheet - Page 3

SOCKET CLASS 1 DIV 2

PYF14A-E-US

Manufacturer Part Number
PYF14A-E-US
Description
SOCKET CLASS 1 DIV 2
Manufacturer
Omron
Series
MY4Hr
Type
Socketr
Datasheets

Specifications of PYF14A-E-US

Number Of Positions
14
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
MY4H Relays
For Use With
MY4ZH-USDC24 - RELAY GP 4PDT 3A 24VDCMY4ZH-USDC12 - RELAY GP 4PDT 3A 12VDCMY4ZH-USAC24 - RELAY GP 4PDT 3A 24VACMY4ZH-USAC110/120 - RELAY GP 4PDT 3A 110/120VACMY4ZH-DC24 - RELAY GP 4PDT 3A 24VDCMY4ZH-AC24 - RELAY GP 4PDT 3A 24VACMY4ZH-AC110/120 - RELAY GP 4PDT 3A 110/120VACMY4H-USDC100/110 - RELAY GP 4PDT 3A 110/110VDCMY4H-USAC24 - RELAY GP 4PDT 3A 24VACMY4HDC100/110 - RELAY GP 4PDT 3A 100/110VDCZ1225 - RELAY 4PDT 110/120AC HERM SEALEDZ1224 - RELAY 4PDT 24VDC HERM SEALEDZ1223 - RELAY 4PDT 12VDC HERM SEALED
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
PYF14AEUS
Z2650

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PYF14A-E-US
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
H3YN
Engineering Data
H3YN-4/-41
Electrical Life Expectancy (Reference Value)
H3YN-2/-21
H3YN-4-Z/-41-Z
ELECTRICAL SERVICE LIFE
5,000
1,000
5,000
1,000
500
200
5,000
1,000
500
200
500
100
60
24 VDC,
resistive
load
Load current (A)
Load current (A)
Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1).
Load current (A)
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1).
220 VAC, resistive load
250 VAC, cosφ = 1
24 VDC, cosφ = 1
250 VAC, cosφ = 1
24 VDC, cosφ = 1
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 5 VDC (P reference value).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 1 mA at 1 VDC (P reference value).
Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases,
a life of 100,000 operations can be expected.
The minimum applicable load is 0.1 mA at 1 VDC (P reference value).
3
5,000
1,000
5,000
1,000
500
200
500
200
Load current (A)
Load current (A)
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
250 VAC, cosφ = 0.4
24 VDC, L/R = 7 ms
H3YN