R99-04 FOR G5F Omron, R99-04 FOR G5F Datasheet - Page 3

MOUNTING BRACKET -G7J

R99-04 FOR G5F

Manufacturer Part Number
R99-04 FOR G5F
Description
MOUNTING BRACKET -G7J
Manufacturer
Omron
Series
G7Jr

Specifications of R99-04 FOR G5F

Accessory Type
Mounting Bracket, Plate
Associated Relay Series
G7J
Termination Style
Screw
Mounting Style
Screw
Width
28 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
G7J Series
For Use With
G7J-4A-TDC6 - RELAY GP PWR 4PST QC TERMG7J-4A-TDC48 - RELAY GP PWR 4PST QC TERMG7J-4A-TDC24 - RELAY GP PWR 4PST QC TERMG7J-4A-TDC12 - RELAY GP PWR 4PST QC TERMG7J-4A-TDC100 - RELAY GP PWR 4PST QC TERMG7J-4A-TAC24 - RELAY GP PWR 4PST QC TERMG7J-4A-TAC200/240 - RELAY GP PWR 4PST QC TERMG7J-4A-TAC100/120 - RELAY GP PWR 4PST QC TERMG7J-4A-BDC48 - RELAY GP PWR 4PST SCREW TERMG7J-3A1B-TDC6 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TDC48 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TDC12 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TDC100 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TAC50 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TAC24 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TAC200/240 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-TAC100/120 - RELAY GP PWR 3PST-NO/1NC QCG7J-3A1B-BDC12 - RELAY PWR 3PST-NO/1NC 25AG7J-3A1B-BAC24 - RELAY PWR 3PST-NO/1NC 25AG7J-2A2B-TDC6 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TDC48 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TDC24 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TDC12 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TDC100 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TAC50 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TAC24 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TAC200/240 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-TAC100/120 - RELAY GP PWR DPST-NO/NC QC TERMG7J-2A2B-BDC12 - RELAY PWR DPST-NO/NC 25AG7J-2A2B-BDC110 - RELAY PWR DPST-NO/NC 25AG7J-2A2B-BDC100 - RELAY PWR DPST-NO/NC 25AG7J-2A2B-BAC50 - RELAY PWR DPST-NO/NC 25AG7J-4A-B-DC24 - RELAY PWR 4PST 25A 24VDCG7J-4A-B-DC12 - RELAY PWR 4PST 25A 12VDCG7J-4A-B-AC24 - RELAY PWR 4PST 25A 24VACG7J-4A-BAC200/240 - RELAY PWR 4PST 25A 230VACG7J-4A-BAC100/120 - RELAY PWR 4PST 25A 120VACG7J-3A1B-B-DC24 - RELAY PWR 3PST-NO/1NC 25A 24VDCG7J3A1BBAC200/240 - RELAY PWR 3PST-NO/1NC 25A 230VACG7J3A1BBAC100/120 - RELAY PWR 3PST-NO/1NC 25A 120VACG7J-2A2B-B-DC48 - RELAY PWR DPST-NO/NC 25A 48VDCG7J-2A2B-B-DC24 - RELAY PWR DPST-NO/NC 25A 24VACG7J-2A2B-B-AC24 - RELAY PWR DPST-NO/NC 25A 24VACG7J2A2BBAC200/240 - RELAY PWR DPST-NO/NC 25A 230VACG7J2A2BBAC100/120 - RELAY PWR DPST-NO/NC 25A 120VAC
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R99-04
R99-04
R99-04FORG5F
R9904
R9904FORG5F
Z1238
Specifications
■ Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and
■ Contact Ratings
Note: The values in parentheses indicate values for a bifurcated contact.
■ Characteristics
AC
DC
Contact mechanism
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Contact resistance (see note 2)
Operate time (see note 3)
Release time (see note 3)
Max. operating frequency
Insulation resistance (see note 4)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Error rate (see note 6)
Ambient temperature
Ambient humidity
Weight
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum voltage is one that is applicable to the Relay coil at 23°C.
Rated voltage
24 VAC
50 VAC
100 to 120 VAC
200 to 240 VDC
12 VDC
24 VDC
48 VDC
100 VDC
±15% for DC coil resistance. (The values given for AC rated current apply at 50 Hz or 60 Hz.)
Item
75 mA
36 mA
18 to 21.6 mA
9 to 10.8 mA
167 mA
83 mA
42 mA
20 mA
Rated current
Double break
Ag alloy
NO: 25 A at 220 VAC (24 A at 230 VAC)
NC: 8 A at 220 VAC (7.5 A at 230 VAC)
NO: 25 A (1 A)
NC: 8 A (1 A)
250 VAC
NO: 25 A (1 A)
NC: 8 A (1 A)
50 mΩ max.
50 ms max.
50 ms max.
Mechanical: 1,800 operations/hr
Electrical:
1,000 MΩ min. (at 500 VDC)
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
4,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
2,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
10,000 V between coil and contact (with 1.2 x 50 µs impulse wave)
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: NO:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: NO:100 m/s
Mechanical: 1,000,000 operations min. (at 1,800 operations/hr)
Electrical:
100 mA at 24 VDC (bifurcated contact: 24 VDC 10 mA)
Operating: –25°C to 60°C (with no icing or condensation)
Operating: 5% to 85%
PCB terminal:
Screw terminal:
Quick-connect terminal: approx. 140 g
Resistive load (cos φ = 1)
---
---
---
---
72 Ω
288 Ω
1,150 Ω
5,000 Ω
Coil resistance
1,800 operations/hr
NC:10 to 26 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
NC:20 m/s
100,000 operations min. (at 1,800 operations/hr) (see note 5)
2
2
approx. 140 g
approx. 165 g
2
75% max. of rated
voltage
Must-operate
voltage
Inductive load (cosφ = 0.4)
15% min. of rated
voltage
10% min. of rated
voltage
Must-release
voltage
110% of rated
voltage
Max. voltage
NO: 25 A at 30 VDC
NC: 8 A at 30 VDC
125 VDC
Resistive load
Approx. 1.8 to
2.6 VA
Approx. 2.0 W
consumption
Power
G7J
3