XS2W-D421-D81-A Omron, XS2W-D421-D81-A Datasheet - Page 27

no-image

XS2W-D421-D81-A

Manufacturer Part Number
XS2W-D421-D81-A
Description
M12 4p M/F 2m CONNECTOR
Manufacturer
Omron
Series
XS2r
Datasheets

Specifications of XS2W-D421-D81-A

Cable Type
Round
Connector Type
Circular 04 pos Female to Male
Length
6.56' (2.00m)
Color
Gray
Shielding
Unshielded
Usage
Industrial Environments - IP67
Svhc
No SVHC (15-Dec-2010)
Cable Assembly Type
Sensor
Cable Length
2m
Connector Type A
M12 Female Socket
Connector Type B
M12 Male
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
XS2WD421D81A
Assembly Procedure for XS2C/XS2G Connector Assemblies
(1) Connector and Cable External Diameters
Note: When connecting a commercially available cable to a connector
(2) Component Insertion
Crimping/Soldering Connectors
Straight Connectors
Angled Connectors
Screw-on Connectors
Confirm that you have all of the required parts.
Connectors for 6-, 4-, and 3-mm-diameter Cables (i.e.,
Cables that are 5 to 6, 4 to 5, and 3 to 4 mm in diameter
respectively) are available. When assembling a Connector
used with a cable, make sure that the external diameter of
the Connector is suited to that of the cable.
Connectors for 6-mm-diameter Cables use white cable
clamps. Connectors for 4- and 3-mm-diameter Cables use
black cable clamps.
A watertight bushing for 6-mm-diameter Cable has no
stripe, that for 4-mm-diameter Cable has a single stripe, and
that for 3-mm-diameter Cable has two stripes.
As shown in the above illustration, connect the above
components to the Cable with its end processed.
Insulation caps and insulation tubes are included with
5-core Connectors (XS2C-D5S@ and XS2G-D5S@).
*
*
1.Rings are not required with 7-mm and 8-mm cables.
2.Insert the waterproof bushing for 7-mm and 8-mm
assembly, use a cable with an outside diameter of 3 to 6 mm and core
sizes of 0.18 to 0.75 mm
for soldering connectors.
cables in the direction shown in the diagram.
* A ring is not required for Screw-on Connectors.
Cover
Cover
Cover
Cover
2
for crimping connectors and 0.5 mm
Ring ∗1
Ring (L-shaped models only) ∗
Watertight
bushing
Watertight
bushing
Watertight
bushing
Watertight bushing
Cable clamp
Cable clamp
Cable
clamp
Cable clamp
Cap
Cap
Cap
Cap
∗2
2
maximum
(3) Wiring (Processing Cable Ends)
Crimping
Wiring
Soldering Connectors
Crimping Connectors
Strip 10 mm of the Cable sheath and 4 mm of each core.
Before soldering cores and solder cup pins together, solder-
coat each of them.
The following conditions are recommended for soldering
each solder cup pin.
Soldering iron: 30 to 60 W
Soldering temperature: 280 C to 340 C
Soldering period: 3 s max.
The length marked A should be 6.5 mm max., otherwise
the proper degree of protection of the connector will not be
maintained.
Strip 14 mm of the Cable sheath and 4 mm of each core.
Make sure that each core is not damaged and its end
strands are not spread out.
Mount the XY2F-0003 Locator to DMC's AFM8 (M25520/2-
01) Crimping Tool, both of which are sold separately, and
set the selector dial of the Crimping Tool to 6 for the XS2U-
@@21 and to 7 for the XS2U-@@22.
After mounting the crimping pins to the Locator, fully insert
the cores to the crimping pins.
Squeeze the handle of the Crimp Tool to press-fit the cores
to the crimping pins.
(Squeeze the handle firmly until the handle automatically
returns to the release position.)
After press-fitting the cores to the pins, insert the pins into
the pin clamp as shown in the illustration. Then make sure
that the lead colors correspond to the pin clamp numbers
that are identical to the connector pin numbers.
Pin clamp
Press
6
±0.5
1 to 1.5
∗A
XS2
27

Related parts for XS2W-D421-D81-A