Operating Force Max
6.5N
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
2.5A
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Contact Form
1 NC / 1 NO
Contact Rating
10 Amps at 120 VoltsAC, 240 VoltsAC
Actuator
Roller Plunger
Operating Force
6.5 N
Termination Style
Conduit
Ingress Protection
IP67
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Slow-action (1NC/1NO) (2NC/1NO)
B-16
(See note 2.)
(See note 3.)
(See note 4.)
(See note 4.)
(See note 1.)
(See note 2.)
(See note 3.)
(See note 4.)
(See note 5.)
(See note 6.)
(See note 7.)
(See note 7.)
DOF min.
DOF min.
DOT min.
DOT min.
MD max.
PT (2nd)
PT (2nd)
OF max.
PT max.
OF max.
PT max.
PT max.
RF min.
OT min.
RF min.
OT min.
Model
Model
OP
OP
OP
TT
TT
Safety Limit Switch
6.5 N
1.5 N
2 mm
4 mm
1 mm
18.2
(6 mm)
3.2 mm
20 N
6.5 N
1.5 N
2 mm
(2.9 mm)
2.8 mm
(1 mm)
4 mm
18.2
17.4
(6 mm)
3.2 mm
20 N
D4N-@B31
D4N-@D31
D4N-@A31
D4N-@C31
D4N-@131
D4N-@231
D4N-@E31
D4N-@F31
0.5 mm
0.5 mm
0.5 mm
6.5 N
1.5 N
2 mm
4 mm
1 mm
28.6
(6 mm)
3.2 mm
20 N
6.5 N
1.5 N
2 mm
(2.9 mm)
2.8 mm
(1 mm)
4 mm
28.6
28 0.8 mm 36 0.8 mm 26.1
(6 mm)
3.2 mm
20 N
D4N-@B32
D4N-@D32
D4N-@A32
D4N-@C32
D4N-@E32
D4N-@F32
D4N-@132
D4N-@232
0.8 mm
0.8 mm
D4N
5.0 N
0.8 N
4 mm
5 mm
1.5 mm
37 0.8 mm 27 0.8 mm
(9 mm)
5.8 mm
20 N
5.0 N
0.8 N
4 mm
(5.2 mm)
4 mm
(1.5 mm)
5 mm
37 0.8 mm 27 0.8 mm
(9 mm)
5.8 mm
20 N
D4N-@B62
D4N-@D62
D4N-@A62
D4N-@C62
D4N-@162
D4N-@262
D4N-@E62
D4N-@F62
5.0 N
0.8 N
4 mm
5 mm
1.5 mm
(9 mm)
4.8 mm
20 N
5.0 N
0.8 N
4 mm
(4.3 mm)
4 mm
(1.5 mm)
5 mm
(9 mm)
4.8 mm
20 N
D4N-@B72
D4N-@D72
D4N-@A72
D4N-@C72
D4N-@E72
D4N-@F72
D4N-@172
D4N-@272
0.8 mm
Note: 1. Variation occurs in the simultaneity of contact opening/
Note: 1. These PT values are possible when the NC contacts are
2. Only for snap-action models.
3. Reference value.
4. Only for slow-action models. For safe use, always make
2. These PT values are possible when the NO contacts are
3. Only for MBB models.
4. Reference values for MBB models.
5. Only for MBB models.
6. Reference value.
7. For safe use, always make sure that the minimum values or
closing operations of 2NC, 2NC/1NO, and 3NC contacts.
Check contact operation.
sure that the minimum values or greater are provided.
open (OFF).
closed (ON).
greater are provided.