H5CX-L8D-N DC12-24/AC24 Omron, H5CX-L8D-N DC12-24/AC24 Datasheet - Page 47

no-image

H5CX-L8D-N DC12-24/AC24

Manufacturer Part Number
H5CX-L8D-N DC12-24/AC24
Description
8-PIN, RLY OUT, Limit, Instant DC12-24/AC24
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-L8D-N DC12-24/AC24

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12 ~ 24VDC, 24VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H5CXL8DNDC1224AC24
Z3000
Safety Precautions (Common)
Refer to Safety Precautions for All Timers.
Note: The following precautions are common for all H5CX models.
■ Precautions for Safe Use
The following precautions must be observed to ensure safety.
Operating and Storage Conditions
• Do not use in locations affected by excessive vibration or shock, or
• Do not use the product in locations subject to dust, corrosive
• Separate the input signal devices, input signal cables, and the
• Separate the product from the source of static electricity when
• Organic solvents (such as paint thinner), as well as very acidic or
• Use the product within the ratings specified for temperature and
• Do not use the product in locations where condensation may occur
• Store at the specified temperature. If the H5CX has been stored at
Usage Precautions
• Make sure that the voltage applied is within the specified range,
• The load current must be within the rated current.
• Ensure that the power is turned OFF before changing DIP switch
• Pay attention to terminal polarity to ensure correct wiring.
• Make sure that the fluctuation of the supply voltage is within the
• Apply the power supply voltage through a relay or switch in such a
• Leaving the H5CX with outputs ON at a high temperature for a long
Loose screws may occasionally result in fire or malfunction. Tighten
the terminal screws securely. The recommended tightening torque
is 0.5 N·m.
There may occasionally be a risk of explosion. Do not use the
product where flammable or combustion gases are present.
This may occasionally cause electric shock, fire or malfunction.
Never disassemble, repair or modify the product.
This may occasionally cause electric shock, fire or malfunction.
Do not allow metal fragments or lead wire scraps to fall inside this
product.
If both the power supply for the input device and that for the timer
are not insulated, unwanted current from the AC power supply
may occasionally burn out or damage the internal parts. Always
use an insulated power supply for the timer.
in locations subject to exposure to water or oil.
gases, or direct sunlight.
product from the source of noise or high-tension cables producing
noise.
using the product in an environment where a large amount of static
electricity is produced (e.g., forming compounds, powders, or fluid
materials being transported by pipe).
basic solutions might damage the outer casing of the H5CX.
humidity.
due to high humidity or where temperature changes are severe.
a temperature of less than –10°C, allow the H5CX to stand at room
temperature for at least 3 hours before use.
otherwise the internal elements of the counter may be damaged.
settings. Changing DIP switch settings with the power turned ON
may result in electric shock due to contact with terminals subject to
high voltages.
permissible range.
way that the voltage reaches the rated value within 2 s. If the
voltage is applied gradually, the power may not be reset or unstable
output operations may result.
time may hasten the degradation of internal parts (such as
electrolytic capacitors). Therefore, use the product in combination
with relays and avoid leaving the product as long as more than 1
month with the output turned ON.
CAUTION
• When the product is operated with no-voltage input (NPN input),
• Install a switch or circuit-breaker that allows the operator to
• The H5CX’s panel surface is water-resistive (conforming to NEMA
• Tighten the two mounting screws on the Adapter. Tighten them
approximately 14 V is output from the input terminals, so connect a
diode if the external power supply is less than 14 V.
immediately turn OFF the power, and make sure it is labeled
clearly.
4, UL Type 4X, and IP66). In order to prevent the internal circuit
from water penetration through the space between the H5CX and
operating panel, attach a waterproof packing (Y92S-29) between
the H5CX and installation panel and secure the waterproof packing
with the Y92F-30 Flush-mounting Adapter.
alternately, a little at a time, so as to keep them at an equal
tightness. If the panel screws are tightened unequally, water may
ingress inside the panel.
T
X
0.5 to 1 mm
2
/b
X
1
T/a
It is recommended that the space between
the screw head and the adapter should be
0.5 to 1 mm.
0 V
X
1
/a
Sensor
Input
X
2
X
1
/a
X
Auxiliary relay
(e.g., MY Relay)
H5CX-B
47