Si3016-KS Silicon Laboratories Inc, Si3016-KS Datasheet - Page 40

Telecom Line Management ICs Line-Side device for processors

Si3016-KS

Manufacturer Part Number
Si3016-KS
Description
Telecom Line Management ICs Line-Side device for processors
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheet

Specifications of Si3016-KS

Product
Modem Module
Interface Type
Wire
Supply Current
0.3 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Package / Case
SOIC-16
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3016-KS
Manufacturer:
SI
Quantity:
20 000
Part Number:
Si3016-KSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Si3016
Register 19. International Control 4
Reset settings = 0000_0000
40
Bit
7:3
2
1
0
Name
Type
Bit
LVCS[4:0] Line Voltage/Current Sense.
Name
DOD
OPD
OVL
D7
Represents either the line voltage, loop current, or on-hook line monitor depending on the
state of the MODE, OH, and ONHM bits.
On-Hook Voltage Monitor (2.75 V/bit).
00000 = No line connected.
00001 = Minimum line voltage (V
11111 = Maximum line voltage (87 V ± 20%).
The line voltage monitor full scale may be modified by changing R5 as follows:
V
Off-Hook Loop Current Monitor (3 mA/bit).
00000 = Loop current is less than required for normal operation.
00001 = Minimum normal loop current.
11110 = Maximum normal loop current.
11111 = Loop current is excessive (overload).
Overload Detected.
This bit has the same function as ROV in Register 17 but will clear itself after the overload has
been removed. See "4.15. Billing Tone Detection" on page 19. This bit is only masked by the
off-hook counter and is not affected by the BTE bit.
0 = Normal receive input level.
1 = Excessive receive input level.
Recal/Dropout Detect.
When the line-side device is off-hook, it is powered from the line itself. If this line-derived
power supply collapses, such as when the line is disconnected, this bit is set to 1. Sixteen
frames (16/Fs) after the line-derived power supply returns, this bit is set to 0. When on-hook,
this bit is set to 0.
0 = Normal operation.
1 = Line supply dropout detected when on-hook.
Overload Protect Detected.
0 = Inactive.
1 = Overload protection active.
Note: See description of overload protect operation (OPE bit).
MAX
= V
MIN
Overload > 140 mA in all modes except CTR21.
Overload > 54 mA in CTR21 mode.
D6
+ 4.2 (10M + R5 + 1.6 k)/[(R5 +1.6 k)*5]
LVCS [4:0]
R
D5
MIN
Rev. 1.0
= 3 V ± 0.5 V).
D4
Function
D3
OVL
D2
R
DOD
D1
R
OPD
D0
R

Related parts for Si3016-KS