JIC-125 JONARD, JIC-125 Datasheet - Page 2

Tools, Fiber Optic Stripper

JIC-125

Manufacturer Part Number
JIC-125
Description
Tools, Fiber Optic Stripper
Manufacturer
JONARD
Datasheet

Specifications of JIC-125

For Use With
Fiber Optic Cables
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
FIBER OPTIC STRIPPERS
MAINTENANCE GUIDELINES
These strippers are preset at the factory and cannot be adjusted or calibrated. The tool may be periodically
checked for proper operation, and may be cleaned with a fine plastic bristled brush to remove debris from
the openings. The openings may be cleaned with (dry) compressed air.
Evaluation
Visual - check for damage to the tool such as: rust on the ground surfaces, rough operation of the handles,
bent missing or damaged tool stop or deformation of the adjacent area.
Functional - The tool should only be used to strip fiber and the fiber should be subjected to normal qualification
tests. The buffer fiber used for these tests should be standard 125 m fiber . The stripping of the fiber should be
performed by a trained technician.
Optical - The opening should be viewed with an optical comparator with a magnification of 50X to 100X power.
When performing the evaluations the tool should be held closed with moderate hand pressure and placed flat
on a fixture so that the ground faces are perpendicular to the angle of viewing. The opening should form a
complete round circle. The guide/cutting surfaces should overlap completely. The tool hole opening ranges
should adhere to the following specifications:
125 m opening range should be 130-175 m
250 m opening range should be 350-450 m
2-3mm opening range should be 1.55-1.70mm
It is important to note that the ground surfaces must be held perpendicular to the viewing angle as deviation
from this will distort the shape and size of the opening. Tools should be tested at least every 6 months or after
performing the equivalent of (500) 25mm strips, whichever occurs first. The test period should be reviewed
annually to determine if more frequent testing is required. Tools should be stored clean and dry to eliminate
surface corrosion. Any tool that fails to meet established standards should be replaced.