LCR55A Amprobe, LCR55A Datasheet - Page 2

LCR METER WITH TRANSISTOR TEST

LCR55A

Manufacturer Part Number
LCR55A
Description
LCR METER WITH TRANSISTOR TEST
Manufacturer
Amprobe
Type
LCRr
Datasheet

Specifications of LCR55A

Rohs Compliant
NA
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
LCR55A Handheld Component Tester
Specifications
Amprobe® Test Tools
Function
Resistance
Continuity
Diode Test
Microwave Diode Test
Capacitance
Inductance
Transistor Test
Overload Protection
Resolution
Open Circuit Voltage
Audible Indication
Response Time
Test Current
Test Voltage
Display
Test Current
Test Voltage
Display
Test Frequency
Temperature Coefficient
Test Frequency
Temperature Coefficient
hFE Range
hFE Base Current
hFE Voltage C - E
Iceo Range, Leakage Current
Resistance
Capacitance
Continuity
Diode Test
Micro Wave Diode Test
Inductance
(23 °C ± 5 °C, < 75 % R.H. non-condensing)
20 W
200 W
2 k W to 2 M W
20 M W
10 m W in 20 W range
20 W range: 6.5 V dc
200 W range: 3.0 V dc
All other ranges: 1.2 V dc
2 k W range: Tone at R < 30 W
800 ms approx.
1 mA (approximately)
3.0 V DC
Forward junction voltage
0.6 mA approximately
7.0 V DC typical
Forward junction voltage
200 pF to 200 nF
2 μF to 200 μF
200 μF < 1000 μF
1000 μF > 2000 μF
Note: In lower ranges, subtract 6 points residual offset reading from result
200 pF to 2 μF: 1000 Hz
20 μF to 200 μF: 100 Hz
2000 μF: 10 Hz
< 0.5 μF: 0.1%/°C
> 0.5 μF: 0.2%/°C
200 μH
2 to 200 mH
2 mH to 200 H
200 μH to 2 H ranges: 1000 Hz
20 H to 200 H ranges: 100 Hz
< 0.5 H: 0.2%/°C
> 0.5 H: 0.5%/°C
0 to 1000
3 μA approximately
3.0 V DC approximately
10 nA to 20 μA
350 V DC or AC RMS
0.1 A/250 V fast acting fuse
350 V DC or AC RMS
350 V DC or AC RMS
350 V DC or AC RMS
0.1 A/250 V fast blow fuse
Range
± (2.0 % rdg + 2 dgts)
± (1.5 % rdg + 1 dgt)
± (3.0 % rdg + 1 dgt)
± (1.0 % rdg + 1 dgt)
± (2.0 % rdg + 1 dgt)
± (3.0 % rdg + 3 dgts)
± (5.0 % rdg + 5 dgts)
± (5.0 % rdg + 30 dgts)*
± (3.0 % rdg + 20 dgts)*
± (5.0 % rdg + 20 dgts)*
± 1.2 % rdg (zero adjust)
± (0.5 % rdg + 3 dgts)
± (0.5 % rdg + 1 dgt)
Accuracy
*For values of Q ≤ 7